CAT 3
Fault
Torch mount cannot
be attached
CAT 3 does not
activate the stop
signal
The CAT 3 does not
reset to the zero
position
CAT 3 triggers
despite there not
being a fault
Tab. 13
Troubleshooting
11 Disassembly
NOTICE
• Please also consult the operating instructions for the welding
components, such as the power source and compressed air line.
Cause
• Wrong torch mount used
• CAT 3 mounting flange is defective
• Cable not connected between the
CAT 3 and the cable assembly
• Cable defective
• CAT 3 switch defective
• Mounted load is too heavy
• Mechanical defect
• Attachment parts (bracket etc.) not
correctly connected
• Mounted load is too heavy
• Robot speed is too high
DANGER
Risk of injury due to unexpected start-up
The following instructions must be adhered to throughout all maintenance,
servicing, assembly, disassembly and repair work:
• Switch off the power source.
• Close the compressed air supply.
• Close the gas supply.
• Switch off the entire welding system.
• Pull the mains plug at the robot welding power source.
11 Disassembly
Troubleshooting
• Use the correct torch mount
• Send the CAT 3 for repair
• Connect the cable
• Replace the cable
• Send the CAT 3 for repair
• Reduce the mounted load
• Observe the data provided by the
manufacturer
• Send the CAT 3 for repair
• Check if the attachment parts are
properly connected
• Adapt the load to the
specifications
 3.1 Technical data on page EN-7