Important! The fitting must be installed, flushed
and tested after the valid norms!
Assembly
1
Flush through the supply pipes.
2
Place the mixer including the sealing
washer in position on the basin / bidet.
3
Slide the fixation piece including the washer
over the threaded pins and tighten the nuts.
4
Connect the supply pipes to the isolation
valves; cold right - hot left.
5
Connect the pull rod to the pop-up waste.
The hot and cold supplies must be of equal
pressures.
Operation
The mixer is activated by lifting the lever handle.
Turning to the left = warmer water,
turning to the right = cooler water.
Test certificate
DVGW
4
All manuals and user guides at all-guides.com
P-IX
SVGW
P-IX
9625/IA
English
Technical Data
Rate of flow:
Operating pressure:
Recommended operating pressure:
MPa
Test pressure:
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Hansgrohe single lever mixers can be used
together with hydraulically and thermically
controlled continuous flow heaters if the flow
pressure is at least 0,15 MPa.
Spare parts see page 3
1
handle
1.1 screw cover
2
flange
Cap, gold
3
nut
4
cartridge cpl.
5
aerator (10)
aerator gold plated
6
pull rod
7
fixing set
8
connection hose
9
aerator
ACS
12 l/min 0,3 MPa
NF
WRAS
max. 1 MPa
0,1 – 0,5
1,6 MPa
max. 80° C
65° C
31792000
96338000
96656000
96656990
96690000
92730000
13955000
94980990
96657000
96016000
97206000
13085000
KIWA

Publicidad

loading

Este manual también es adecuado para:

Avista 31728000