Care and maintenance

Danger!
!
Before any care and maintenance
work on the unit draw out the mains plug.
Caution!
When changing the oil, dispose of
any waste oil only at authorised collection
points.
Safety inspection/
Maintenance contract
You can arrange with your dealer to have
a regular safety inspection carried out or to
have a maintenance contract. Please seek
advice.
Before each use
Check connecting cable for damage
(risk of getting an electric shock), have
a damaged connecting cable replaced
without delay by authorised Customer
Service personnel or an electrician.
Check high-pressure hose for damage
(danger of explosion), replace
a damaged high-pressure hose
without delay.
Check unit (pump) for any leaks. 3 drops
per minute are allowable and can
appear on the underside of the unit.
Seek the help of Customer Service if
leaks are more serious.
Every week
Check oil level in oil reservoir: if the oil is
milky (water in oil), seek the help of
Customer Service immediately.
Clean strainer at the water connection.
Clean the filter at the suction hose for
detergent.
Annually or after 500
operating hours
Change the oil
For oil quantity and type see Technical
Specifications.
Remove the cover of oil reservoir.
Lay unit on its side and drain oil into
a suitable container.
Fill slowly with fresh oil; air bubbles have
to escape.

Frost protection

Caution!
Water which has frozen in the cleaner
can destroy parts of it. At best store the unit
in a heated room during the winter or empty
it or rinse it thoroughly with antifreeze.
Empty the unit
Unscrew supply hose and high-pressure
hose from the unit.
Leave the unit running until the pump
and lines have emptied (max. 1 minute).
Putting in antifreeze
For longer intervals between operations,
pumping antifreeze through the unit is to
be recommended. By this means also
you obtain a sure protection against
corrosion.