Nominal voltage
Current consumption
Charging voltage
Float Charging Voltage
Service Mode Voltage
Reactivation Voltage
Max. charging current
Minimum battery voltage
Operational temperature
Cooling
Charging characteristic
Battery types
Battery capacity
Weight (without charging power)
To start the charging, service operation, the connected battery must have a
minimum voltage of 3 V or more. Otherwise, the device will not start the charge.
The quality of charging voltage and charging current is very important. High ripple
leads to heating of the battery and wear of the positive electrode. The battery
chargers from Berner are characterized by a very clean voltage and a smooth
current with low ripple !!!
TELLERERKL
• High frequency charger BHFL399 portable.
• Mains cable with Schuko plug and IEC socket, 2 m in length.
• Mounted charging cable with fully insulated metal pole terminals 3 m in length.
• This user manual
The charger must be protected from heavy contamination, liquids and moisture, as
this may damage the internal electronics.
If the power cord or charging leads are damaged, they must be replaced. The case
of the charger can be cleaned with a dry cloth. Disconnect the power plug from the
socket before cleaning.

TECHNICAL SPECIFICATIONS

DELIVERY
CARE / MAINTENANCE
19
85 V – 264 VAC 47-63 Hz
5,2 A (by maximum charging current)
14,3 VDC (± 0,3%)
13.6 VDC (± 0,3%)
13,9 VDC ( 0,3%)
max.15,5 VDC ( 0,3%)
40 A ± 3%
3 V
-20°C – 50°C
Fan controlled by temperature
IUoU
Lead-Acid, Lead-GEL, AGM
25-400 Ah
2,6 kg