Safety Precautions
Eng
Caution
Thermo King MD-200 MT Multi-Temperature condensing systems are shipped with a 35-69 kPa (5-10 psi) holding
charge of nitrogen. This holding charge may be safely vented into the atmosphere.
IMPORTANT: Do not release the holding charge until necessary to prevent moisture from entering the system.
SPECTRUM™ S-2 remote evaporators are shipped with a 35-69 kPa (5-10 psi) holding charge of nitrogen. This
holding charge may be safely vented into the atmosphere.
SEVERE COMPRESSOR DAMAGE will result from operating the engine/motor before completing the system
installation which includes: installing the components, releasing the condensing unit holding charge, releasing the
remote unit holding charge, soldering the refrigeration lines, leak testing the system, evacuation and clean-up, and
charging the system.
Recover Refrigerant
At Thermo King, we recognize the need to preserve the environment and limit the potential harm to the ozone layer
that can result from allowing refrigerant to escape into the atmosphere.
We strictly adhere to a policy that promotes the recovery and limits the loss of refrigerant into the atmosphere.
v