Specifications; Performance Specifications; Interferent Gases And Vapors; Instrument Replacement Parts - Ohio Medical Corporation MiniOX 1 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

X
1
MiniO
®
Oxygen Analyzer
Section 3

Specifications

Performance Specifications

Range
Display Resolution
Linearity
Accuracy
Low Battery Indicator
Warm-Up Time
Operating Temperature
Range
Storage Temperature range -20
Humidity
Power Requirements
Battery Life
Instrument 4-5/8" x 2-1/2" x 1-1/2"
Dimensions
Sensor
Cable Length
Sensor Type
Sensor Life
Shelf Life
Response
FLOW
Time mea-
RATE LI-
sured with
TERS/MIN.
deflector and
2
mounted in a
5
22 mm tee
adapter @
10
25
C
o

Interferent Gases and Vapors

%BY
INTERFER-
VOLUME
ENT
(DRY GAS)
Carbon Dioxide
12%
Cyclopropane
50%
Diethyl Ether
20%
Enflurane
4%
Halothane
5%
3-1
All manuals and user guides at all-guides.com
0-100% O
2
0.1% O
increments
2
+2% of full scale
+2% of full scale
"LO BAT" appears on the
display
None required
0
to 40
C (32
to 104
F)
o
o
o
o
to 55
C (-4
to 131
F)
o
o
o
o
0 to 95% RH
One 9-volt alkaline battery
Approximately 1,400 hours
1-15/16" OD x 1-7/8" long
10 Ft. (3m) fully extended
Galvanic fuel sensor 0-100%
O
2
Over one year in normal
medical conditions
Sensors, as shipped, can be
stored for a maximum of 6
months without degradation
of life
80% OF
97% OF
CHANGE
CHANGE
(SECONDS)
(SECONDS)
13
21
12
20
11
19
INTERFERENT EQUIVA-
LENT OF PERCENT O
<0.1%
<0.1%
<1.5%
<0.5%
<0.9%
P/N 711462 (Rev.3) 02/2016
Interferent Gases and Vapors
INTERFERENT
Helium
Methoxyflurane
Nitrogen
Nitrous Oxide

Instrument Replacement Parts

DESCRIPTION
Case Screw
Dovetail Mounting Bracket
40x3/8" stainless stee screw (set
of 4)
ITEM
Alkaline battery, 9-Volt
Coiled Cable
Deflector
Home Care Kit (see Appendix A)
Mounting Bracket,Pole
Mounting Bracket, wall
Operation/Maintenance Manual
CD
Operation Manual (Printed)
Oxygen Sensor
Sensor Retaining Strap
Tee Adapter
Carrying Case
Sleeve Adapter
Inspection and Servicing
2
Calibration
Enclosure Replacement
Circuit Board Replacement
Button and Sensor Jack
Replacement
Section3, Specifications
% BY VOL-
INTERFERENT
UME (DRY
EQUIVALENT
GAS)
OF PERCENT O
80%
<0.2%
4%
<2.3%
80%
<0.2%
80%
<0.8%
PART NUMBER
637408
474606
450000

Accessories

PART NUMBER
628817
472045
470687
474682
474664
10023945
600700
711462
406931
634249
473021
710462
474667

Servicing

SVC-101
SVC-102
SVC-103
SVC-104
SVC-105
2

Publicidad

Tabla de contenido
loading

Tabla de contenido