Application
Can be used in conjunction with:
• Pressurised storage heaters
• Thermally-controlled instantaneous heaters
• Hydraulically-controlled instantaneous heaters
Operation with unpressurised storage heaters (open water
heaters) is not possible.
Safety notes
• Installation is only possible in frost-free rooms.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty.
Technical data
• Max. flow:
• Flow pressure
- min.
- recommended
- greater than 72.5 psi, fit pressure reducing valve
• Max. operating pressure
• Test pressure
• Temperature
- max. (hot water inlet)
• Voltage supply:
6V lithium battery type CR-P2
• Automatic safety shut-off
(factory setting):
• Run-on time (factory setting):
• Reception range according to Kodak Gray Card, grey side,
8x10", landscape (factory setting):
• Type of fitting protection:
• Water connection:
General functions
• Thermal disinfection:
• Remaining battery capacity:
Programme 1 functions (factory setting)
• Cleaning mode:
• Automatic flushing:
• Thermal disinfection time:
Further pre-set programmes can be selected via the sensor
system.
Special accessories
Further settings and special functions are available
via the infrared remote control (Prod. No. 36 206).
1
English
Installation
Flush pipes thoroughly before and after installation
(observe EN 806).
Fitting
Refer to the dimensional drawings on fold-out page I and fold
out page II, Fig. [1].
Fasten fitting to wash basin, see Figs. [2] to [4].
Connection
The cold water supply must be connected on the right,
hot water supply on the left.
1. Screw connection hose by using the filter (B) to the
adapter (A), see Fig. [5].
2. Connect adapter (A) to the service valves.
Connecting the voltage supply
1.9 L/min or 0.5 gpm/60 psi
1. Secure bracket (D1) using screws and plugs, see Fig. [6].
2. Insert battery (D2) in battery housing (D4) and fit lid (D3).
7.25 psi
Observe correct polarity.
14.5 - 72.5 psi
3. Connect plug-in connector between electronics cable (C)
and battery housing (D), see Fig. [7].
145 psi
4. Engage battery housing (D) in bracket (D1).
232 psi
Open hot and cold water supply and check connections
158 °F
for watertightness.
Setting temperature limiter
60 s
1 s
Prod. no. 36 328:
1. Remove screw (E) and detach lever (F), see Fig. [8].
approx. 5"
2. Remove screw (G) and remove temperature limiter (H).
IP 59 K
3. Remove feather key (I) from temperature limiter (H) and
cold - right
reinsert in the desired position. The grooves in the
hot - left
temperature limiter (H) correspond to the temperatures
that can be selected, see Fig. [9].
Assemble in reverse order.
activatable
readable
Prod. no. 36 329:
1. Remove screw (J), see Fig. [10].
activatable
2. Pull off stop ring (K).
inactive
3. Using a screwdriver, turn mixer spindle (L) clockwise
3.5 min
until the desired maximum temperature is reached.
4. Refit stop ring (K) and secure with screw (J).
Operation
The infrared electronics emit invisible, pulsed light.
The sensor system is adjusted so that water flow is
initiated when the hands approach the vicinity of the spout.
When the hands are withdrawn from the vicinity of the
spout, water flow is stopped after 1 s (factory setting).
The range of the sensor system is dependent upon the
reflective properties of the detected object.
Automatic safety shut-off
After 60 s (factory setting) of continuous detection of an object,
the infrared electronics automatically stop the water flow.

Publicidad

loading

Este manual también es adecuado para:

Eurosmart cosmopolitan e 36 329