Specifications PSM 1 12 24
Operating voltage:
110–240 V AC, 50/60 Hz
Operating current: 265 mA
Output voltage: 24 V DC +/-3 %
Output current: 0.5 A
Fusing: T 0.8
Protection class: II
Ambient temperature:
-10 °C to +50 °C
Horizontal pitch (HP): 1
Dimensions (mm) W x H x D:
17.5 x 96 x 68
Specifications NEO006.0-I-X-12
Operating voltage:
100–240 V AC, 50/60 Hz
Operating current: 160 mA
Output voltage: 12 V DC +/-5 %
Output current: 0.6 A
Cable length (mm): 3000
Ambient temperature:
+5 °C to +40 °C
Dimensions (mm) W x H x D:
36 x 59 x 41
Simplified EU Declaration of
Conformity
The manufacturer: S. Siedle & Söhne
Telefon und Telegrafenwerke OHG
Address: Bregstraße 1,
D-78120 Furtwangen
declares that the product:
Type:
IQ BTS
Meets the essential requirements of
the following EU Directives:
Radio Equipment Directive
2014/53/EU
The full text of the EU Declaration
of Conformity is available at the fol
lowing internet address:
https://www.siedle.de
Pfad: Service > Handwerk und
Handel > Produktkatalog >
IPSysteme > Siedle IQ > IQ BTS
Siedle IQ BTS
Replacement of BTS 850-... with
IQ BTS
Only the programming (door call to
BTS) is retained.
• Switch off the voltage
• Remove the BTS 850-...
• Fit the IQ BTS, do not close the
upper part of the housing.
• Switch on the voltage
• Press and hold the light button on
the IQ BTS. Attach the housing to
the base plate at the top and close
with gentle pressure.
• Keep the light button pressed until
an acknowledgement tone is heard.
• Press the required call button on
the door station three times within
30 seconds. Each time the button is
pressed an acknowledgement tone
is then heard on the IQ BTS.
• Successful programming is sig
nalled on the IQ BTS and the door
station with the storey call.
• The system is now ready for opera
tion.
5