Siemens SITRANS LR200 Guia De Inicio Rapido página 11

Ocultar thumbs Ver también para SITRANS LR200:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 103
Device nameplate (FM/CSA)
The FM/CSA Intrinsically Safe connection
drawing number 23650529 can be downloaded from the product page of our website at:
www.siemens.com/LR200. Go to Support > Installation Drawings > Level Measurement >
Continuous - Radar.
• For wiring requirements: follow local regulations.
• Approved dust-tight and water-tight conduit seals are required for outdoor NEMA 4X /
type 4X / NEMA 6, IP67, IP68 locations.
Instructions specific to hazardous area installations
• Refer to
Under the entity evaluation concept, SITRANS LR200 has the following characteristics:
(input voltage) U
i
(input current) I
i
(input power) P
i
(internal capacitance) Ci
(internal inductance) Li
Entity Concept:
The Entity Concept allows interconnection of intrinsically safe apparatus to associated
apparatus not specifically examined in such combination. The criteria for interconnection is
that the voltage and current which intrinsically safe apparatus can receive and remain
intrinsically safe, considering faults, must be equal to or greater than the output voltage (Uo)
and output current (Io) levels which can be delivered by the associated apparatus, considering
faults and applicable factors.
In addition, the maximum unprotected capacitance (Ci) and Inductance (Li) of the intrinsically
safe apparatus, including interconnecting wiring, must be equal to or less than the
capacitance and inductance which can be safely connected to associated apparatus.
FISCO Concept
Under the FISCO evaluation concept, SITRANS LR200 has the following characteristics:
(input voltage) U
i
(input current) I
i
(input power) P
i
(internal capacitance) Ci
(internal inductance) Li
Note: For complete details and instructions regarding the FISCO Concept The FM/CSA
connection drawing number 23650529 can be downloaded from the product page of our
website at: www.siemens.com/LR200. Go to Support > Installation Drawings > Level
Measurement > Continuous - Radar.
A5E32153438
SITRANS LR200 (PROFIBUS PA) – QUICK START MANUAL
= 24 V
= 250 mA
= 1.2 W
= 0
= 0
= 17.5 V
= 380 mA
= 5.32 W
= 0
= 0
on page 11.
Page EN-9

Publicidad

Tabla de contenido
loading

Tabla de contenido