The programming phase is used to configure the behaviour of the control panel in managing input devices (detectors, input modules,
manual buttons) and output devices (output modules, fire alarms) in managing and signalling a fire alarm condition.
Refer to the programming manual for a detailed description of the functions and possibilities offered by the control panel.
Programming from personnel computer
The control panel can also be programmed and configured using the configurator software, by directly connecting a PC through the
USB port. Proceed by reading the configuration present in the control panel by downloading it to the PC.
Configure all the features of the fire alarm system and save the configuration on the PC itself (programming can also be done with the
control panel disconnected from the PC).
Finally, transfer the new configuration present in the PC to the control panel to end the configuration process.
Refer to the programming manual and the configurator software for a detailed description of the functions and possibilities offered by
the control panel.
CE LABELS
According to the EN54 standards, below are reported the CE labels containing all the necessary information:
Via Bologna, 188/C - 10154 Torino - Italy
0051-CPR-0243
DoP n. 0051-CPR-0243
1043/550
Control and indicating equipment for fire
detection and fire alarm system for buildings
EN 54-2: 1997 + A1:2006
EN 54-4: 1997 + A1:2002 + A2:2006
100-240 V-15/+10%, 50/60 Hz, 3 A
Vout: 26 V⎓, ± 10%, 4.85 A
Circuit module: 1
Options with requirements list:
7.8 Output to fire alarm device
7.9 Output to fire alarm routing equipment
7.11 Delay to outputs
7.12 Co-incidence detection
8.3 Fault signals from points
8.9 Output to fault warning routing equipment
9.5 Disablement of addressable points
10
Test condition
DS1043-261
09
0051
09
Via Bologna, 188/C - 10154 Torino - Italy
Control and indicating equipment for fire
detection and fire alarm system for buildings
EN 54-4: 1997 + A1:2002 + A2:2006
100-240 V-15/+10%, 50/60 Hz, 3 A
Vout: 26 V⎓, ± 10%, 4.85 A
Circuit modules: 2 up to 4
Options with requirements list:
7.8 Output to fire alarm device
7.9 Output to fire alarm routing equipment
7.11 Delay to outputs
7.12 Co-incidence detection
8.3 Fault signals from points
8.9 Output to fault warning routing equipment
9.5 Disablement of addressable points
10
Test condition
14
09
0051
09
0051-CPR-0242
DoP n. 0051-CPR-0242
1043/560
EN 54-2: 1997 + A1:2006
LBT20960