Function of buttons and meaning of signalling LED.
In stand-by
Button
Short pressure (<1 s)
- When the handset is on hook, it activates the electrical door
lock release of the last external station that made a call.
- When the handset is off, activates conversation with the last
external station that made a call.
Long pressure (>3 s)
- When the handset is engaged, if programmed on the last
external station that made the call, it activates EC/EM where
present.
- When the handset is off, it enters in conversation with the
last external station that made a call.
Button
Short pressure (<1 s)
The function depends on the address stored in the button, in
detail:
- address of another flat or concierge unit, after picking up
the handset, it calls the address of that flat;
- address of another room in the same flat, after picking up
the handset, it calls the device on the other room;
- address of an actuator, the actuator is activated/deactivated;
- address of an external unit you connect to the door unit
without having previously received the call If the handset is
on hook, the door lock is opened directly, if the handset is
off, you enter automatically in conversation.
Long pressure (>3 s)
Same functions described for short pressure.
Button
Short pressure (<1 s)
The function depends on the address stored in the button, in
detail:
- address of another flat or concierge unit, after picking up
the handset, it calls the address of that flat;
- address of another room in the same flat, after picking up
the handset, it calls the device on the other room;
- address of an actuator, the actuator is activated/deactivated;
- address of an external unit you connect to the door unit
without having previously received the call If the handset is
on hook, the door lock is opened directly, if the handset is
off, you enter automatically in conversation.
Long pressure (>3 s)
Activates/deactivates the office function. The operation of the
office function is indicated by the icon LED
Only if the activation time of the office function is set to zero
(function disabled), the same functions as described for short
press can be activated.
Button
Short pressure (<1 s)
The function depends on the address stored in the button, in
detail:
- address of another flat or concierge unit, after picking up
the handset, it calls the address of that flat;
- address of another room in the same flat, after picking up
the handset, it calls the device on the other room;
- address of an actuator, the actuator is activated/deactivated;
- address of an external unit you connect to the door unit
without having previously received the call If the handset is
on hook, the door lock is opened directly, if the handset is
off, you enter automatically in conversation.
Long pressure (>3 s)
Enables/disables the exclusion of all ringtones. When the
ringtones are excluded, the icon LED
Flashes slowly
All ringtones are excluded.
Steadily on
Door open signalling.
Flashes quickly
Office function activated.
- 8 -
Mi 2576
During call and conversation:
Short pressure (<1 s)
Activates the electrical door lock release of the external station
to which you are connected.
Long pressure (>3 s)
If programmed on the external station which has made the call,
it activates EC/EM where present.
Short pressure (<1 s)
The only function that can be executed is the activation/deacti-
vation of a relay if the address of a relay is stored.
Long pressure (>3 s)
Same function described for short pressure.
Short pressure (<1 s)
The only function that can be executed is the activation/deacti-
vation of a relay if the address of a relay is stored.
Long pressure (>3 s)
Activates/deactivates the office function. The operation of
the office function is indicated by the icon LED
flashing rapidly.
rapidly. Only if the activation time of the office function is set
to zero (function disabled), the same function as described for
short press can be activated.
Short pressure (<1 s)
The only function that can be executed is the activation/deacti-
vation of a relay if the address of a relay is stored.
Long pressure (>3 s)
Enables/disables the exclusion of all ringtones.When the
flashes slowly.
ringers are muted, the icon LED
Flashes quickly in call and slowly in conversation when all
ringtones are excluded.
Steadily on
Door open signalling.
Flashes quickly
Office function activated.
Note. The terminals of the devices listed below send the door open signal:
- external stations: PB/GN of C.2124AB and PB/PB of TD2000. with suitable
programming;
- 2281Q relay: IN/GN input port with factory setting.
flashing
flashes as shown below.

Publicidad