GB
Description of Symbols
The rating plate on your tool may show symbols. These represent important
information about the product or instructions on its use.
Wear hearing protection
Wear eye protection
Wear breathing protection
Wear head protection
Wear hand protection
Read instruction manual
Conforms to relevant legislation and safety standards
Environmental Protection
Waste electrical products should not be disposed of with
household waste. Please recycle where facilities exist. Check with
your local authority or retailer for recycling advice
Specification
The following specifications assume a 1-year calibration cycle and
an operating temperature of 18°C to 28°C (64°F to 82°F) at relative
humidity up to 80% unless otherwise noted.
AC Current
(Average sensing, calibrated to rms of sine wave)
Range
Resolution
200A
100mA
1000A
1A
Overload Protection:
Jaw Opening:
AC Voltage
(Average sensing, calibrated to rms of sine wave)
Range
Resolution
600V
1V
Input Impendance:
Overload Protection:
DC Voltage
Range
Resolution
600V
1V
Overload Protection:
Input Impendance:
4
All manuals and user guides at all-guides.com
Accuracy (50Hz - 60Hz)
±(2.5% of reading ±10 digits)
±(2% of reading ±5 digits
for 800A and below
± (3% of reading ±5 digits)
for other current
1000A within 60 seconds
2" (5cm)
Accuracy (50Hz - 500Hz)
±(1.2% of reading ±5 digits)
9MΩ
600V AC/DC on all ranges
Accuracy (50Hz - 500Hz)
±(1% of reading ±2 digits)
600V DC/peak AC on all
ranges
9MΩ
Resistance
Range
Resolution
200Ω
0.1Ω
20KΩ
10Ω
Overload Protection:
Continuity Test
Range:
200Ω
Buzzer Sound:
30+ 20Ω
Overload Protection:
500V DC/rms AC
Environment
Temperature:
Normal Operation:
18˚C-28˚C
Usable Condition:
0˚C-50˚C
Storage:
-20˚C-+60˚C
battery removed and<80% RH
Relative Humidity:
Max. 80%
Measurement Method:
Dual slope integration technical
Reading Rate:
3 reading/sce
Polarity:
Automatic, indicated minus,
assumed plus
Overload Indication:
Blanking of all digits, except
MSD,decimal point and sign
appropiate
Power Requirements:
9V Battery
Battery Life:
Up to 200 hours typical with
Alkaline
Up to150 hours typical with Zinc
Battery Indication:
Display indicates LO BAT when
approximately 20% of battery
life remains
Display:
LCD 3
⁄
digit (1999 count)
1
2
0.5" high
Data Hold:
All function and ranges with this
feature
Weight:
Approx 11 ounces (310 grams)
AC Current:
0.1A to 1000A
AC Voltage:
1V to 600V
DC Voltage:
1V to 600V
Resistance:
200Ω to 2000MΩ
Continuity Test:
30+ 20Ω with audio tone
As part of our ongoing product development, specifications of
Silverline products may alter without notice.
Accuracy (50Hz - 500Hz)
±(1% of reading ±3 digits)
±(1% of reading ±1 digits)
500V DC/rms AC on all ranges
(64˚F-82˚F)
(32˚F-122˚F)
(-30˚F-140F)