Display messages

8
Display messages
NOTE
I
When you start the vehicle or switch on several consumers at once,
the display text
8.1

Control panel warnings

The system control unit has various functions for protecting the device and
the battery. If one of these protective functions has been triggered, this is
shown by the following codes on the display.
Display
Description
text
The battery monitor has
LO
detected low voltage.
The compressor
switches off immedi-
ately and the fan is
switched off after 20 to
30 seconds. The whole
system shuts down after
2 minutes.
The system has
HI
detected a brief or con-
stant over-voltage.
The system has
HO
detected a brief electri-
cal overload and
switches the compressor
off.
The compressor is
switched off. 5 minutes
later, the entire system
will be switched off.
38
All manuals and user guides at all-guides.com
LO
may briefly appear.
Cause
Connection voltage is too
low. The battery capacity
is not sufficient to operate
the system.
A brief over-voltage may
occur when large electri-
cal consumers are
switched off. Constant
over-voltage is the result
of an incorrect connec-
tion voltage.
The current power
requirement of the com-
pressor is too high.
The compressor (driver's
cab) is tilted too far.
RT880/SP950
Remedy
➤ Brief under-voltage: No
action required.
➤ The system switches it-
self off: Charge the ve-
hicle battery or check if
the battery monitor has
been correctly set.
➤ Brief over-voltage: No
action required.
➤ If the display message
"HI" remains visible for a
longer period: Check
the vehicle electronics.
Make sure the connec-
tion voltage is less than
30 volts.
➤ The brief overload is
compensated by the
system by switching off
the compressor. The
compressor starts up
again after a short time.
➤ Once the compressor
has been returned to its
normal position, the
system can be switched
on again.