7
COMMISSIONING
en
30
O P E R A T I N G I N S T R U C T I O N S | WTS26
1
1...3 sec.
2
3
Figure 16: WTS26x-xxxxxx2xAxx, adjusting the sensing range with Teach-Turn adjustment
WTS26x-xxxxxx1xAxx with potentiometer:
The sensing range is adjusted with the potentiometer.
Clockwise rotation: Sensing range increased
Counterclockwise rotation: Sensing range reduced
We recommend placing the object within the sensing range, see figure 9 for an exam‐
ple. Once the sensing range has been adjusted, the object is removed from the path of
the beam, which causes the background to be suppressed. The digital output changes
(table
4).