Appliance does not have sufficient
pressure
1. Check the water supply for adequate de-
livery rate.
2. Pull out the sieve from the water connec-
tion using flat-nose pliers, and clean the
filter under the running water.
3. Appliance ventilation:
a Disconnect the high-pressure hose.
b Switch the appliance on, and operate
the appliance (max. 2 minutes) until
the water exits the high-pressure con-
nection without bubbles.
c Switch the appliance off.
d Reconnect the high-pressure hose to
the appliance.
Strong pressure fluctuations
1. Clean the high-pressure nozzle:
a Remove the dirt / dust from the nozzle
bore using a needle.
b Apply water to the front of the nozzle
bore to rinse it through.
2. Check the water flow quantity.
Appliance is leaking
Slight leakage from the appliance pump
is normal. If the leakage increases,
please contact the next authorised cus-
tomer service site.
Warranty
The warranty conditions issued by our rele-
vant sales company apply in all countries.
We shall remedy possible malfunctions on
your appliance within the warranty period
free of cost, provided that a material or
manufacturing defect is the cause. In a war-
ranty case, please contact your dealer (with
the purchase receipt) or the next author-
ised customer service site.
(See overleaf for the address)
14
Technical data
Power connection
Mains voltage
Mains frequency Hz
Protection class
Type of protection
Current consump-
tion
Water connection
Feed pressure
(max.)
Feed tempera-
ture (max.)
Feed volume
(min.)
Device performance
Working pressure MPa 6.7
Max. permissible
pressure
Water flow rate
Max. flow rate
Dimensions
Weight (without
accessories)
Length
Width
Height
Subject to technical modifications.
English
K2
K2
Power
Power
VPS*
VPS*
KAP
KR
V
230-240 220
50
60
I
I
IP X5
IP X5
A
6.0
6.0
MPa 1.2
1.2
°C
40
40
l/min 8.0
8.0
6.7
MPa 10.0
10.0
l/min 5.0
5.0
l/min 6.0
6.0
kg
11.0
11.0
mm 365
365
mm 175
175
mm 290
290