5.1 - DIAGNOSTICS FOR PROBLEMS AND RELATED INTERVENTIONS
In this paragraph there is a list of the greatest possible number of problems, with related cause and
suggested remedies, that the machine may present during its operation. If the malfunctioning remains, do
not insist by attempting personal solutions, contact the BATTIONI PAGANI S.P.A. technical office,
the same is true if any problems occur that are not foreseen in the following diagnostics.
Any necessary interventions must only be carried out by Mechanical maintenance operators once this
manual has been consulted.
In any case, before intervention on the machine, unless otherwise specified, shut off the machine.
DETECTED MALFUNCTIONING
Low pressure
Excessive heating
The joint is not turning
Excessive noise
6.1 - MAINTENANCE STATUS
The maintenance operations must be carried out with the machine in the conditions described under the item
"MACHINE ISOLATION" .
6.2 - MACHINE ISOLATION
Before carrying out any type of Maintenance or Repairs, it is necessary to proceed with isolating the machine
from the hydraulic supply.
5 - MACHINE USE
PROBABLE CAUSE
1.
Infiltration or air exiting the
hydraulic system.
1.
Excessive pressure.
2.
Excessive revolutions per minute.
3.
Excessive operational time.
1.
Worn worm screw.
2.
Worn toothed rack.
3.
Hydraulic system piping
disconnected / intercepted.
4.
Oil hydraulic control valve
malfunctioning.
1.
Absence of lubrication.
2.
Internal rollers worn.
6 - MAINTENANCE
REVOBLOCK motorised joint
use and maintenance manual
REMEDY
1.
Eliminate infiltrations.
1.
Reduce pressure.
2.
Reduce revolutions per minute.
3.
Reduce operational time.
1.
Replace.
2.
Replace. Equip with toothing
covering.
3.
Connect / open interceptions.
4.
Replace.
1.
Lubricate.
2.
2. Replace rollers.
pag. 47