3.3
Machine settings and programs
Changing the Set Point of the temperature on the controller
The unit comes with a factory default set point ( 32°F Refrigerators). These set
values will make the unit perform at its maximum capacity. Therefore, it is not
recommended to change the set point. If set point needs to be changed, follow the
next steps.
1. Push the SET button for one second. You should see a flashing number.
Release the button.
2. Press the up and down arrows to increase or decrease the set
temperature. Then press the set button to save the new set point.
Note:
The maximum value you can set in the controller is: For refrigerators: 5°C
(40°F)
3. If you wish decrease the value of the set point for a new temperature,
press the button DOWN arrow (see the picture below). Press this button
to reach the desired value. Release the button and then press the SET
button to keep, and save, the new value.
Note:
The minimum value you can set in the controller is: For refrigerators: -1°C
(30°F)
Manual Defrost
To select manual defrost, hold the button DOWN arrow for 5 seconds. The snow
flake icon will appear on the display. When this icon is solid it indicates that the
equipment is in Defrost mode.
To exit manual defrost, hold the DOWN button arrow for 5 seconds. The snow
flake icon will turn off. Wait 2 minutes for the compressor to start
MAINTENANCE
4.1 General safety rules.
4.2 Machine cleaning and maintenance routine.
4.3 Machine disposal.
4.1
General safety rules
Neglecting the condenser coil cleaning procedures WILL VOID YOUR WARRANTY
associated with the compressor or cost to replace the compressor!
Proper cleaning of stainless steel requires soft cloths or plastic souring pads.
Never use steel pads, wire brushes or scrapers!
10