Ber Measurement Mode Selection - Promax PROLINK-3 Premium Manual De Instrucciones

Ocultar thumbs Ver también para PROLINK-3 Premium:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

USER'S MANUAL. PROLINK-3/3C
For the power measurement of a digital channel to be correct it is essential to
have previously defined the channel bandwidth using the Channel BW function, in the
TV mode functions menu (see section '4.9.4.11 Channel Bandwidth').

4.9.1.5 BER measurement mode selection

The PROLINK-3/3C
of digital signals depending on the type of used modulation.
To select the BER measurement mode:
1)
Select the TV operating mode. If present operating mode is the spectrum analyser
mode press key
2)
Select the terrestrial band for the measurement of QAM or COFDM modulated
signals or the satellite band for the measurement of QPSK modulated signals.
Available frequency ranges are:
QAM signals
COFDM signals
QPSK signals
3)
Select the DIGITAL operating mode by means of the key
4)
Select the BER measurement mode: to do this press key
rotary selector [4] to select the BER measuring mode, next, to activate it press the
rotary selector [4] or key
Before measuring the BER or analysing the Wrong Packets in the Transport
Stream MPEG-2 / DVB is necessary to define some parameters concerning the digital
signal, which are described in the following section (see section '4.9.1.5.1. Measuring
BER of QAM Digital Channels (QAM)'). To see its present value or to modify it, being in
the BER measuring screen, press the rotary selector, it will appear a multiple-choice
menu showing the functions relative to the BER measurement on the screen.
Once set-up the necessary parameters for tuning and measuring the digital
signals, depending on used modulation type, the PROLINK-3/3C
possibility of visualizing the decoded digital TV images (see section '4.9.3 Decoding
MPEG-2 / DVB Channels, access to Digital Services').
Only for models with this option available
06/2005
Premium
Premium
offers three ways to measure the error rate (BER)
[21].
47 MHz to 862 MHz
40 MHz to 870 MHz
950 MHz to 2150 MHz
[22].
[20].
[22] and turn the
Premium
offers the
Page 37

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Prolink-3c premium

Tabla de contenido