Some DiSEqC commands need to define an associated parameter (i.e. On/Off, a
numerical value, A/B...), when any of these commands is selected first option for the
associated parameter appears automatically at its right, to change it turn the rotary
selector and to validate it press the rotary selector (see DiSEqC commands table).
Once the DiSEqC command is defined, the cursor will pass to the following line, if
you want to define a new command proceed as for the first one, if you do not want to
add any command press key
After the commands sequence is created it is possible to modify it. To modify the
sequence press key
command you want to make the change and then press the rotary selector [4]: Insert
function will appear on the screen, by turning the rotary selector it is possible to select
Delete and Edit functions. Once the desired function appears on the screen (Insert,
Delete or Edit) press the rotary selector. If you select Delete function the command will
be removed from the sequence, if you select Insert or Edit functions, you must define
the new command as previously described.
Once commands sequence is defined, to send it to the peripherals press key
[31] repeatedly until you have selected the Send function and then press the
rotary selector [4]. At the same time as DiSEqC commands are sent these appear on
the lower side of the monitor. If Send function does not appear on the monitor, place the
cursor over the Clear function and turn the rotary selector.
It is possible to delete the whole of the commands sequence, to do this press key
[31] repeatedly until you have selected the Clear field and then press the rotary
selector [4]. If Clear function does not appear on the monitor, place the cursor over the
Send function and turn the rotary selector.
To exit DiSEqC function place the cursor over the Exit field and then press the
rotary selector [4].
REMARK: When disconnecting the unit, the commands sequence will NOT be lost.
It is possible to execute a specific DiSEqC program using a direct access key
(see '4.13 Direct Access to Functions'). This enables you to change specific
configurations from the Spectrum Analyser Mode, useful during the parameter
adjustment process in an installation.
It is also possible to execute DiSEqC programs using the Datalogger function if
their names are included in the automatic reading acquisition sequence (see '4.12.1
Storing a Measurement Configuration (STORE)').
Next table shows the DiSEqC commands available:
Page 74
[31].
[31] repeatedly until you have positioned the cursor on the
USER'S MANUAL. PROLINK-3/3C
Premium
06/2005