Grounding And Ac Power Cord Connections; Assembly Instructions; Control Panel - Schumacher 98-1 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Position yourself and free end of cable as far away from battery as possible – then connect NEGATIVE
7.4
(BLACK) charger clip to free end of cable.
Do not face battery when making final connection.
7.5
When disconnecting charger, always do so in reverse sequence of connecting procedure and break first
7.6
connection while as far away from battery as practical.
A marine (boat) battery must be removed and charged on shore. To charge it on board requires
7.7
equipment specially designed for marine use.
8.

GROUNDING AND AC POWER CORD CONNECTIONS

This battery charger is for use on a nominal 120 volt circuit and has a grounded plug. The charger must be
8.1
grounded, to reduce the risk of electric shock. The plug must be plugged into an outlet that is properly installed
and grounded in accordance with all local codes and ordinances. The plug pins must fit the receptacle (outlet).
Do not use with an ungrounded system.
DANGER: Never alter the AC cord or plug provided – if it does not fit the outlet, have a proper grounded
8.2
outlet installed by a qualified electrician. An improper connection can result in a risk of an electric shock
or electrocution.
NOTE: Pursuant to Canadian Regulations, use of an adapter plug is not allowed in Canada. Use of an
adapter plug in the United States is not recommended and should not be used.
USING AN EXTENSION CORD
8.3
The use of an extension cord is not recommended. If you must use an extension cord, follow these guidelines:
• Pins on plug of extension cord must be the same number, size, and shape as those of plug on charger.
• Ensure that the extension cord is properly wired and in good electrical condition.
• Wire size must be large enough for the AC ampere rating of charger, as specified:
Length of cord (feet)
AWG* size of cord
*AWG-American Wire Gauge
9.

ASSEMBLY INSTRUCTIONS

9.1
Remove all cord wraps and uncoil the cables prior to using the battery charger.

10. CONTROL PANEL

LED INDICATORS
CLAMPS REVERSED/BAD BATTERY (red) LED flashing: The connections are reversed.
CLAMPS REVERSED/BAD BATTERY (red) LED lit: The charger has detected a problem with the
battery. See Troubleshooting for more information.
CHARGING (yellow/orange) LED lit: The charger is charging the battery.
CHARGED/MAINTAINING (green) LED lit: The battery is fully charged and the charger is in maintain mode.
NOTE: See Operating Instructions for a complete description of the charger modes.
RATE SELECTION
Use this button to select one of the following:
6<>2A CHARGE/MAINTAIN – For charging small and large batteries. Not recommended for industrial
applications. The charger will automatically adjust the charging current, based on battery size, in order to
charge the battery completely, efficiently and safely.
BOOST – For quickly adding energy to a severely discharged or large capacity battery prior to Engine Start.
ENGINE START – Provides additional amps for cranking an engine with a weak or run-down battery.
Always use in combination with a battery.
25
50
100
150
18
16
12
10
• 7 •

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

98-3

Tabla de contenido