• Do not lift more weight than you can handle. Use additional man power or mechanical lifting equipment to safely
handle placement of the screen.
• Do not tighten screws with excessive force. Overtightening can cause damage to mount. Tighten M10 x 15 mm
screws (E) to 40 in. • lb (4.52 N.M.) maximum torque.
Mounting Flat Panel Screen
For Dedicated PLP Plate (not evaluated by UL):
3
Refer to PLP model instruction sheet for attachment
of dedicated PLP plate to screen.
Install two M10 x 15 mm screws (provided with
dedicated PLP plate) into top two holes of dedicated
PLP plate leaving 1/4" of exposed thread as shown
in fi gure 3.1.
DEDICATED PLP PLATE
ADAPTER PLATE
3-1
Insert two M10 x 15 mm screws (E) into bottom holes of adapter plate as shown in fi gure 3.3 or 3.4. Tighten all
fasteners with 6 mm allen wrench (H).
DEDICATED PLP PLATE
ADAPTER PLATE
fi g. 3.3
WARNING
1/4"
M10 X 15 MM SCREW
fi g. 3.1
E
9 of 46
For Universal Adapter Bracket: Hook M10 x 15 mm
screws into keyslots of wall arm adapter plate (A) as
shown fi gure 3.2.
SCREEN NOT
SHOWN FOR
CLARITY
ADAPTER PLATE
ADAPTER PLATE
ISSUED: 10-30-09 SHEET #: 095-9297-2 12-04-09
B
1/4"
M10 X 15 MM SCREW
fi g. 3.2
B
E
fi g. 3.4
A