Installing Your Appliance; Cabinet Clearances - AGA marvel ML24RFP0 Serie Instrucciones De Instalación, Operación Y Mantenimiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Select Location
The proper location will ensure peak performance of your
appliance. We recommend a location where the unit will
be out of direct sunlight and away from heat sources. To
ensure your product performs to specifi cations, the recom-
mended installation location temperature range is from 55
to 100°F (13 to 38°C).
Cabinet Clearance
Ventilation is required from the bottom front of the appli-
ance. Keep this area open and clear of any obstructions.
Adjacent cabinets and counter top can be installed around
the appliance as long as the front grille remains unob-
structed. Overlay door models with articulated hinges are
intended for built-in applications only.
WARNING
!
An optional stacking kit is required to stack products.
Failure to use a stacking kit could result in personal
injury. Contact your dealer or Aga Marvel customer
service at 800-223-3900 to order.
CAUTION
!
Front Grille
Do not obstruct the front grille. The openings within the
front grille allow air to fl ow through the condenser heat ex-
changer. Restrictions to this air fl ow will result in increased
energy usage and loss of cooling capacity. For this reason
it is important this area not be obstructed and the grille
openings kept clean. AGA MARVEL does not recommend
the use of a custom made grille as air fl ow may be restrict-
ed. (See Figure 2).
I NSTALLING YOUR APPLIANCE
Leveling Legs
Adjustable legs at the front and rear corners of the appli-
ance should be set so the unit is fi rmly positioned on the
fl oor and level from side to side and front to back. The over-
all height of your Marvel appliance may be adjusted higher
(by turning the leveling leg out, CCW) and lower (by turning
the leveling leg in, CW) dimensions as shown in Table "A".
To adjust the leveling legs, place the appliance on a solid
surface and protect the fl oor beneath the legs to avoid
scratching the fl oor. With the assistance of another person,
lean the appliance back to access the front leveling legs.
Raise or lower the legs to the required dimension by turning
the legs. Repeat this process for the rear by tilting the appli-
ance forward using caution. On a level surface check the
appliance for levelness and adjust accordingly.
The front grille screws may be loosened and the grille ad-
justed to the desired height. When adjustment is complete
tighten the two front grille screws. (See Figure 5).
4
Front Leveling
Legs
Figure 2
Model
Door Style
ML24
S
ML24
P
Table A
Front Grille,
keep this area
open.
Rear
Leveling
Legs
Minimum
Maximum
Height
Height
33
"
34
"
3
3
4
4
(85.7 cm)
(88.3 cm)
34"
35"
(86.4 cm)
(88.9 cm)

Publicidad

Tabla de contenido
loading

Tabla de contenido