Adjusting The Sensors - NAMCO MAZAN Manual Del Operador

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10
5-5-3

Adjusting the Sensors

Sensor adjustment is performed while power to the machine is ON. To
prevent electric shock, accident or injury, do not touch any parts other
than those specified in the following sections.
The Frame assembly is an important part in the correct function of the sensors.
Please check that each part of the Frame assembly is fitted correctly and that the
reflective material on the inside of the Frame assembly is clean and smooth (no
cracks or bubbles).
Ensure that the glass sensor covers are clean, both inside and outside.
When "(I/O PCB ERROR") is displayed on the screen, check the connection of the
USB cable first.
After "NAOMI" LOGO is displayed, the self-test is started.
If adjustment of the sensors is incorrect, the error message is displayed on the
screen. Perform the following procedures to adjust the sensors for correct operation.
When conducting the sensor adjustment, do not place any object, arm or sword
inside the sensor area.
Infrared light deteriorates through glass. Please adjust the sensors without
removing the glass covers.
1.
Remove the Control Panel.
2.
Enter the Test Mode
and then select Sensor Level Check
displayed.
The four graphs correspond to the four sensors.
1
LEFT SENSOR ASSY
SENSOR 1
SENSOR 2
2
(see 6-2 page 46)
3
MONITOR
RIGHT SENSOR ASY
4
PLAYER
Page 40
(see 7-6 page 72)
and select I/O Test
(6-2-3-2 page
(6-2-3 page 50)
51). The graph screen is