GB
TECHNIC L CH R CTERISTICS
Supply voltage
Frequency
Operating temperature
Maximum consumption during switching
GEX691
GEX692
GEX693
Minimum idle consumption
Transfer time (maximum values)
GEX691
GEX692
GEX693
Maximum number of operations
GEX691
GEX692
GEX693
Maximum number of operations/hour
GEX691
GEX692
GEX693
∂
Relative humidity: 90%.
EMC T BLE
Immunity
Electrostatic discharges
Electromagnetic H.F. field
Fast transients (Burst)
Fast transient (surge discharge)
Conducted disturbances
Electromagnetic field,
industrial frequency
Voltage dips, interruptions
and voltage variations
Emission
Harmonic current emissions
Voltage disturbance
Radiated emission
EN 61000 is equivalent to IEC 61000 - EN 55011 is equivalent to CISPR11.
CRITERION : Normal service in determined limits.
CRITERION B: Transient alteration of service. The equipment returns to normal operation without the intervention of the operator.
Test level 3: Typical industrial environment, without special installation measures.
Test level 4: Severe industrial environment.
Special level: Environment with more stringent electromagnetic compatibility requirements.
230V C/DC (±15%)
50/60Hz
-40...+65°C∂
0.695
1.965
3.075
0.225
0.192s
0.168s
0.148s (GE1000E/ET4 - GE1250E/ET4); 0.175s (GE1600E/ET4)
10,000
10,000
7,000
120
120
60
Standard
Criterion
Level
EN 61000-4-2
Special
EN 61000-4-3
3
EN 61000-4-4
4
EN 61000-4-5
Special
EN 61000-4-6
3
EN 61000-4-8
4
EN 61000-4-11
-
B
-
Standard
Criterion
Level
EN 61000-3-2
-
3
-
3
EN 55011
-
3
EN 55011
3
Characteristics
±8kV air discharge; ±4kV equipment discharge
10V/m
±4kV power supply; ±2kV signal supply
±4kV power supply L1-L2;
Generator impedance 2Ω (wave 1.2/50µs)
10V supply and signal
Field intensity 30 /m
60% Un - 1000ms
95% Un - 5000ms
Characteristics
0.02 total current (manual mode)
0.04 total current (automatic mode)
Compliant
Compliant
17