• There must be an air-break switch.
• After installation, the consumer must operate the air conditioner
correctly according to this manual, keep a suitable storage for
maintenance and moving of the air conditioner in the future.
• Fuse of indoor unit: T 3.15A 250VAC or T 5A 250VAC. Refer to the
screen printing on the circuit board for the actual parameters,
which must be consistent with the parameters on the screen print-
ing.
• For 7 to 12k models, fuse of outdoor unit: T 15A 250VAC or T 20A
250VAC. Refer to the screen printing on the circuit board for the
actual parameters, which must be consistent with the parameters
on the screen printing.
• For 14k to 18k models, fuse of outdoor unit: T 20A 250VAC.
• For 21 k to 30k models, fuse of outdoor unit: T 30A 250VAC.
• Appliances that are permanently connected to fixed wiring, and
have a leakage current that may exceed 10 mA, it is advisable to
include the installation of a residual current device (RCD) having a
rated residual operating current not exceeding 30 mA.
WARNING: RISK OF ELECTRIC SHOCK THAT CAN
CAUSE INJURY OR DEATH: DISCONNECT ALL RE-
MOTE ELECTRIC POWER SUPPLY BEFORE SERVIC-
ING.
• The maximum length of the connecting pipe between the indoor
and outdoor units should be less than 5 meters. A larger length
will affect the efficiency of the air conditioner.
• This appliance should not be used by children younger than 8
years old.
• Do not let children play with the appliance.
• Cleaning and user maintenance work should not be carried out by
children.
• The batteries in remote control must be recycled or disposed of
properly.
• Disposal of Scrap Batteries: Please discard the batteries as sorted
municipal waste at the accessible collection point.
• If the appliance is wired directly to the house line, then it must be
fitted with means for disconnection from the power supply. These
means should have a contact separation in all poles that provide
full disconnection under over voltage category III conditions. These
means must be incorporated in the fixed wiring in accordance with
the wiring rules.
• The appliance must be installed in accordance with the national
wiring regulations.