Output Parameters - CARLO GAVAZZI IO-Link PD30CTP R BP IO Serie Manual De Instrucciones

Fotocélula
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 129

7.2.4. Output Parameters

Index Dec
Parameter Name
Channel 1 Setup (SO1)
64 (0x40)
Stage Mode
1 (0x01)
Input selector 1
2 (0x02)
Timer Mode
3 (0x03)
Timer Scale
4 (0x04)
Timer Value
5 (0x05)
Logic function
7 (0x07)
Output Inverter
8 (0x08)
Channel 2 Setup (SO2)
65 (0x41)
Stage Mode
1 (0x01)
Input selector 2
2 (0x02)
Timer Mode
3 (0x03)
Timer Scale
4 (0x04)
Timer Value
5 (0x05)
Logic function
7 (0x07)
Output Inverter
8 (0x08)
Access
Default value
(Hex)
-
R/W
1 = PNP output
R/W
0 = Disabled timer
R/W
0 = Milliseconds
R/W
R/W
R/W
R/W
0 = Not inverted (Normally Open)
-
R/W
1 = PNP output
R/W
0 = Disabled timer
R/W
0 = Milliseconds
R/W
R/W
R/W
R/W
1 = Inverted (Normally Closed)
Data range
-
0 = Disabled output
1 = PNP output
2 = NPN output
3 = Push-pull output
0 = Deactivated
3 = Dust Alarm 1 (DA1)
1 = SSC 1
4 = Dust alarm 2 (DA2)
5 = Temperature Alarm (TA)
6 = External logic input
7 = Application Functions
0 = Disabled timer
1 = T-on delay
2 = T-off delay
3 = T-on/T-off delay
4 = One-shot leading edge
5 = One-shot trailing edge
0 = Milliseconds
1 = Seconds
2 = Minutes
0
0 ... 32 767
0 = Direct
4 = Set-reset Flip-Flop
0 = Not inverted (Normally Open)
1 = Inverted (Normally Closed)
-
0 = Disabled output
1 = PNP output
2 = NPN output
3 = Push-Pull
4 = Digital logic input (Active high/
5 = Digital logic input (Active low/
6 = Teach-in (Active high)
0 = Deactivated
3 = Dust Alarm 1 (DA1)
1 = SSC 1
4 = Dust alarm 2 (DA2)
5 = Temperature Alarm (TA)
6 = External logic input
7 = Application Functions
0 = Disabled timer
1 = T-on delay
2 = T-off delay
3 = T-on/T-off delay
4 = One-shot leading edge
5 = One-shot trailing edge
0 = Milliseconds
1 = Seconds
2 = Minutes
0
0 ... 32 767
0 = Direct
4 = Set-reset Flip-Flop
0 = Not inverted (Normally Open)
1 = Inverted (Normally Closed)
Rev.00 - 06 .2021 | MAN PD30CTP/R IO-Link EN | © 2021 | CARLO GAVAZZI Industri
Data Type
-
-
UIntegerT
1 = SSC 1
2 = SSC 2
UIntegerT
UIntegerT
UIntegerT
IntegerT
0 = Direct
1 = AND
2 = OR
UIntegerT
3 = XOR
UIntegerT
-
-
UIntegerT
Pull-down)
Pull-up)
1 = SSC 1
2 = SSC 2
UIntegerT
UIntegerT
UIntegerT
IntegerT
0 = Direct
1 = AND
2 = OR
UIntegerT
3 = XOR
UIntegerT
Length
-
8 bit
8 bit
8 bit
8 bit
16 bit
8 bit
8 bit
-
8 bit
8 bit
8 bit
8 bit
16 bit
8 bit
8 bit
39