2.5. Sensor Specific adjustable parameters

Besides the parameters directly related to output configuration, the sensor also have various internal parameters
useful for setup and diagnostics.

2.5.1. Selection of local or remote adjustment

It is possible to select how to set the sensing distance by either selecting the "Trimmer Input" or "Teach-by-wire"
using the external input of the sensor, or to disable the trimmer input by selecting "IO-Link Adjustment" to make
the sensor tamperproof.

2.5.2. Trimmer data

The value of the setpoints can be set from 1 200 ... 70 representing a sensing distance of 1 700 ... 6 600 mm
for PD30CTRR60... or PD30CTPR60... and 500 ... 70 representing a sensing distance of 2 500 ... 5 500 mm
for PD30CTPS50...

2.5.3. Process data configuration

When the sensor is operated in IO-Link mode, the user has access to the cyclic Process Data Variable.
By default the process data shows the following parameters as active: 16 bit Analogue value, Switching
Output1 (SO1) and Switching Output 2 (SO2).
The following parameters are set as Inactive: SSC1, SSC2, DA1, DA2, TA, SC, WDA1, WDA2, AFO1.
However by changing the Process Data Configuration parameter, the user can decide to also enable the status
of the inactive parameters. This way several states can be observed in the sensor at the same time.
NB! If Application functions are selected more options for "Analogue Values" can be selected in the Observation
tab.

2.5.4. Sensor Measurement Selection

The sensor has 3 sensor precision presets, which can be selected depending on the environment:
• Default precision (Filter scaler fixed to 1)
• High precision (Filter scaler fixed to 10 - slow)
• Customized (Filter scaler can be set from 1-255)
Precision can be adjusted via parameter "Filter scaler". See 2.6.9.

2.5.5. Temperature alarm threshold

The temperature at which the temperature alarm will activate can be changed for the maximum and minimum
temperature. This means that the sensor will give an alarm if the maximum or minimum temperature is exceeded.
The temperatures can be set between -50 °C to +150 °C. The default factory settings are, Low threshold -30
°C and high threshold +120 °C.

2.5.6. Safe limits

The Safe limits can be set for the sensor in % of the SP1 and SP2 and can be set individually for SSC1 and
SSC2. It is used for calculating a Stable ON or Stable OFF signals.
• Dust alarm: If the Safe limits are exceeded then the dust alarm is activated, see also Dust alarm description
• Water drop alarm: If the Safe limits are exceeded then the water drop alarm is activated, see also water
drop alarm description.
• Auto Adjust: When the safe limits are reached for the auto adjust function it activates the alarm for cleaning
the sensor face.
• The Green LED is also influenced by the Safe limits and can be used to set up the sensing distance manually
adjusting until the LED lights Stable ON.

2.5.6.1. Stable ON

When the sensor detects a signal that are x % higher (set by Safe limits) than the value for which the output
switches ON, then the sensor is stable ON.
24
Rev.00 - 06.2021 | MAN PD30CTP/R IO-Link EN | © 2021 | CARLO GAVAZZI Industr6