WARNING:
Keep the extension cord clear of the working area.
Position the cord so that it will not get caught on lumber,
tools, or other obstructions while you are working with a
power tool. Failure to do so can result in serious personal
injury.
WARNING:
Check extension cords before each use. If damaged
replace immediately. Never use the product with a
damaged cord since touching the damaged area could
cause electrical shock resulting in serious injury.
GROUND FAULT CIRCUIT INTERRUPTER
See Figure 2.
This unit is equipped with a Ground Fault Circuit Interrupter
(GFCI), which guards against the hazards of ground fault
currents. An example of ground fault current is the current
that would flow through a person who is using an appliance
PRODUCT SPECIFICATIONS
Maximum Pounds Per Square Inch* ........................................................................................................................ 1,800 psi
Maximum Gallons Per Minute ...................................................................................................................................1.2 GPM
Input ..................................................................................................................................... 120 V, AC only, 60 Hz, 13 Amps
*Max. rating determined by PWMA Standard PW101
KNOW YOUR PRESSURE WASHER
See Figure 3.
The safe use of this product requires an understanding of the
information on the product and in this operator's manual as
well as a knowledge of the project you are attempting. Before
use of this product, familiarize yourself with all operating
features and safety rules.
AUTOMATIC DETERGENT INJECTION
SYSTEM
Pour detergent into the soap tank to apply detergent quickly
and easily to your cleaning project. Use of the soap nozzle
will activate the detergent injector at a 20:1 dilution ratio.
CARRYING HANDLE
The pressure washer has a carrying handle for easy transport.
ELECTRICAL
with faulty insulation and, at the same time, is in contact
with an electrical ground such as a plumbing fixture, wet
floor, or earth.
GFCI plugs do not protect against short circuits, overloads,
or shocks.
NOTE: To ensure readiness for use, press the reset button
each time you connect the pressure washer to the power
supply.
The GFCI plug can be tested with the TEST and RESET
buttons.
To test:
 Press the TEST button. You will hear a "click" sound and
the LED light will go out.
 To restore power, press the RESET button. The LED light
will illuminate to indicate power has been restored.
Perform this test monthly to ensure proper operation of the
GFCI.
 To reduce the risk of electric shock the supervisory
circuit must be operated before an appliance is
plugged into any receptacle on the device.

FEATURES

GFCI PLUG
The pressure washer is equipped with a GFCI plug to guard
against the hazards of ground fault currents. This plug does
not protect against short circuits, overloads, or shocks.
HOSE STORAGE
Once the high pressure hose is rolled, hang it on the left side
of the machine using the hook-and-loop strap to secure in
place.
ON/OFF SWITCH
This switch turns the pressure washer on and off.
POWER CORD STORAGE
Once the power cord is rolled, hang it on the right side of the
machine using the hook-and-loop strap to secure in place.