RIB PREMIER 24V Manual Del Usuario página 43

Con b2 24v-crx
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

EVENT
Dip 1 ON (hold-to-run mode)
Or failure of a safety device
Dip 2 ON (full stroke programming)
Dip 2>1 ON (pedestrian stroke programming)
Programming sequence stopped due to intervention of a safety
device
EVENT
No transmitter code entered
Dip 1 > 2 - transmitter code programming for full opening
Dip 1 > 3 - transmitter code programming for pedestrian opening
Dip 1>2> 3 - transmitter code programming for R-AUX relay
Correct transmitter codes programming for full opening and R-AUX
relay
Correct transmitter codes programming for pedestrian opening
Remote control code not present in memory
Memory saturated by remote control codes (1000 codes saved)
Radio code deletion for full opening, pedestrian opening, R-AUX
relay
EVENT
Stop button pressed
Photocell intervention
Edge intervention
Intervention of impact sensor
Failure of a safety device or safety device engaged for too long
Running with emergency batteries (24 vdc)
Emergency batteries low signal
Operation with emergency batteries charged by solar panels
Alarm from edge
Impact sensor alarm
Failed photocells auto-test alarm
Functional block activated by smartphone
Achievement of set cycles
Energy saving activated by smartphone
TABLE SUMMARISING VISUAL AND SOUND ALARMS
SIGNALS DURING PROGRAMMING SEQUENCE
BUZZER STATUS
OFF
OFF
OFF
10 seconds tone with 2 seconds pause
BUZZER STATUS
OFF
OFF
OFF
OFF
1 Tone
1 Tone
OFF
OFF
2 Tones
WARNING SIGNALS DURING OPERATION
BUZZER STATUS
OFF
1 Tone
2 Tones
3 Tones
OFF
OFF
1 Tone every 5 seconds for 1 minute
(It is renewed by giving a command)
OFF
2 Tones every 5 seconds for 1 minute
(It is renewed by giving a command)
3 Tones every 5 seconds for 1 minute
(It is renewed by giving a command)
4 Tones every 5 seconds for 1 minute
(It is renewed by giving a command)
OFF
6 Tones every 5 seconds for 1 minute
(It is renewed by giving a command)
OFF
43
FLASHER STATUS
OFF
Flashes on-OFF 250 ms
OFF
Flashes on-OFF 500 ms
OFF
Flashes on-OFF 500 ms
OFF
On steady
FLASHER STATUS
OFF
Flashes red/green
OFF
Flashes red for 10 seconds
OFF
Flashes green for 10 seconds
OFF
Flashes orange for 10 seconds
OFF
Turns green once
OFF
Turns red once
OFF
Red flash
OFF
Runs 6 green flashes
OFF
Runs 2 green flashes
FLASHER STATUS
LED STATUS AND SIGNAL OUTPUT
OFF
Led DL6 turns OFF
OFF
Led DL7-8 turns OFF
OFF
Led DL9-10 turns OFF
OFF
No led combined
OFF
Led DL1 flashes on-OFF 250 ms
Flashes during
Signal output flashes on-OFF twice for 250 ms
movement
followed by a pause of 2 seconds
Signal output flashes continuously on-OFF for 500
OFF
ms
Signal output flashes on-OFF 3 times for 250 ms
OFF
followed by a pause of 2 seconds
Flashes for 1 minute
No led combined
Flashes for 1 minute
No led combined
OFF
No led combined
OFF
Led DL12 is steady on green.
OFF
No leds matched
OFF
Blue led flashes once every 5 seconds
G
B
DL1 LED STATUS
DL12 LED STATUS