Husky L210VWD Guía De Uso Y Cuidado página 17

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operation (continued)
5
Draining the tank
WARNING: Risk of unsafe operation. Air tanks contain
high pressure air. Keep face and other body parts away
from the drain outlet. Use eye protection [ANSI Z87.1 (CAN/
CSA Z94.3)] when draining, as debris can be kicked up
into the face.
WARNING: Risk from noise. Use ear protection (ANSI
S12.6 (S3.19), as air flow noise is loud when draining.
WARNING: Risk of bursting. Water will condense in the
air tank. If not drained, water will corrode and weaken the
air tank causing a risk of air tank rupture.
NOTE: All compressed air systems generate condensate
that accumulates in any drain point (e.g., tanks, filter,
after-coolers, dryers). This condensate contains lubricating
oil and/or substances which may be regulated and must
be disposed of in accordance with local, state, and federal
laws and regulations.
NOTE: If the drain valve is plugged, release all air
pressure. The valve can then be removed, cleaned,
then reinstalled.
NOTE: Risk of property damage. Drained water from the
air tank may contain oil and rust which can cause stains.
Set the AUTO/OFF switch (8) to the off position.
Slowly bleed the air from the compressor tank
by pulling the safety valve to allow the pressure
to escape from the tank until the pressure is
approximately 20 psi.
Drain water from the tank by opening the drain
valve (9) on the bottom of the tank.
After the water has been drained, close the drain
valve. The air compressor can now be stored.
8
17
Please contact 1-888-43-HUSKY for further assistance.
9
HUSKYTOOLS.com

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

1001 574 543

Tabla de contenido