Victron energy Blue Smart 12/5 Manual De Instrucciones página 16

Ocultar thumbs Ver también para Blue Smart 12/5:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

6.
STORAGE
Keeps the battery at reduced constant voltage to limit
gassing and corrosion of the positive plates.
Slow self-discharge is prevented by an automatic weekly
refresh of the battery with a short absorption charge.
7.
READY
The battery is fully charged when the FLOAT or STORAGE
LED is on.
8.
REFRESH
Slow self-discharge is prevented by an automatic weekly
refresh of the battery with a short absorption charge.
3.2 Lithium-ion (LiFePO₄) batteries
When charging a Lithium-ion battery, the Blue Smart Charger
uses a specific charging algorithm for Lithium-ion batteries, to
ensure optimum performance. Select LI-ION with the mode
button.
3.3 When a load is connected to the battery
A load can be applied to the battery while charging, as long as
the current draw is much lower than the rated output of the
battery charger.
Reconditioning is not possible when a load is connected to the
battery.
Remarks:
a)
Disconnect all loads before attempting to recharge a very
weak or fully discharged lead-acid battery. Loads may be
reconnected once the bulk phase has started.
b)
Disconnect all loads before attempting to recharge a Li-ion
battery when the under voltage protection (UVP) of the
Li˗ion battery has tripped. Loads may be reconnected once
the bulk phase has started.
12

Publicidad

Tabla de contenido
loading

Tabla de contenido