Technical Specifications - Victron energy Blue Smart 12/5 Manual De Instrucciones

Ocultar thumbs Ver también para Blue Smart 12/5:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4. Technical specifications

Blue Smart Charger 120V
Input voltage range
Efficiency
Standby power consumption
Minimum battery voltage
Charge voltage 'absorption'
Charge voltage 'float'
Charge voltage 'storage'
Charge current
Charge current in low current mode
Temperature compensation
(lead-acid batteries only)
Can be used as power supply
Back current drain
Protection
Operating temp. range
Humidity (non condensing)
Battery-connection
120 V AC-connection
Weight
Dimensions (h x w x d)
Safety
Emission
Immunity
12V 5/7/10/15A
110-130 VAC (2-3A)
94%
Starts charging from down to 0V
Normal: 14.4V
High: 14.7V
Li-ion: 14.2V
Normal: 13.8V
High: 13.8V
Li-ion: 13.5V
Normal: 13.2V
High: 13.2V
Li-ion: 13.5V
5 / 7 / 10 / 15A
2 / 2 / 3 / 4A
16 mV/°C (9mV/°F)
0.7Ah/month (1mA)
Reverse polarity
Over temperature
-20 to +60°C (full rated output up to 30°C)
0 to + 140°F (full rated output up to 90°F)
Max 95%
ENCLOSURE
Black and red cable of 1.5 meter (4.9 feet)
Cable of 1.8 meter (5.9 feet) with US NEMA 1-15 plug
0.9kg (2lbs)
12/5, 12/7: 47x95x190mm
1.8x3.7x7.5 inches
0ther: 60x105x190mm
STANDARDS
EN 60335-1, EN 60335-2-29 (UL1236 / CSA C22.2)
EN 55014-1, EN 61000-6-3, EN 61000-3-2
EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
24V 5/8A
95%
0.5W
Normal: 28,8V
High: 29,4V
Li-ion: 28,4V
Normal: 27,6V
High: 27,6V
Li-ion: 27,0V
Normal: 26,4V
High: 26,4V
Li-ion: 27,0V
5/8A
2/3A
32 mV/°C (18mV/°F)
Yes
Output short circuit
0,9kg (2lbs)
24/5: 47x95x190mm
1.8x3.7x7.5 inches
other: 60x105x190mm
15

Publicidad

Tabla de contenido
loading

Tabla de contenido