Instruction Manual - AKO-Agrartechnik BA-1031 Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 7
Specific Operating Instructions
1
2
3
4
5
8
a.) Installation
The unit must, as a rule, be installed vertically with the connections at the bottom and, if possible, protected against rain,
see above picture, left side. In case of wall mounting, it must be mounted against a fireproof wall. For outdoor installation,
a zinc-plated metal casing can be used. This accessory (part No. 44656) protects the unit and also accommodates the
accumulator.
b.) Functional description of the unit
Put unit into service WITHOUT fence and earthing. When connecting the 12V accumulator, be sure to observe the
correct polarities (red + and black -). If the fence light (1) flashes green, the unit is ready for use. If in addition the
accumulator light (2) flashes red, check the 12V accumulator for correct voltage. If the fence light (1) does not flash,
check the polarity of the 12V connecting cable on the accumulator or have the unit checked by a technician. When
operating the unit with solar module or mains adapter, first remove the protective cover (4).
Switch positions:
c.) Functional description with connected fence system ( fence + earth )
Accumulator
Fence light
light (2)
(1) flashes
flashes red
green
1
NO
2
NO
YES
3
YES
4
5
YES
6
NO
If the fence light (1) flashes faster than approx. once per second, the unit must be disconnected at once and checked by
a technician before it can be used again.
For increased running time, a number of Solar modules with support stands can be used. We recommend the
use of a wet accumulator at 12V-85Ah or 12V–110Ah. The accessories for this unit are obtainable through
specialized dealers! Mains adapter: AN3100..... 5500 = Art.-Nr. 371012
!!!Attention: Earth electrodes are not included in the supply (use at least 3 earth electrodes approx. 1m long) !!!
New function in accordance with EN 60335-2-76 A12: 2010
Following a delay time of 15 seconds this device delivers an output energy of no more than 5 joules.
With an increasing load the device increases its output energy after a delay time has lapsed and therefore automatically
adjusts the shock strength to the increased growth, weather conditions and fence status.
This equipment carries a 3-year warranty in accordance with our Warranty Terms & Conditions!
Please see the attached Operating Instructions for safety tips, earthing, commissioning, maintenance of battery
and accumulator, warranty terms and conditions and potential sources of fault!
SERVICE Addresses:
Please contact your specialist dealer
Normal operation with 12V – wet
accumulator; alternatively, the appliance
can be operated with a mains adapter!
Not suited for use in barns!
0 = OFF;
I = reduced current consumption and output power
II = maximum output power and current consumption
Audible
clicks
YES
YES
YES
NO
YES
YES
YES
NO
NO
NO
NO
NO
6
Output voltage
> 3500 V = minimum requirement
< 3500 V; see fault finding in the enclosed
instruction manual (Figure 2, p.5)!
> 3500 V = minimum requirement
and:
< 3500 V; see fault finding in the enclosed
instruction manual (Figure 2, p.5)!
No pulses, deep charge protection activated
See b.) Functional description of the appliance, without fence and earth
3
1 Fence voltage
Indicator light
12V-ACCUMULATOR
2
indicator light
3 2-step switch
Socket for solar / mains
4
adapter + protective cover
12V battery connection
7
5
cable
6 Earth connection
7 Fence connection
8 Fastening holes
12V accumulator
OK ( >12,2V)
OK (>12,2V)
Charge or replace as
soon as possible
Charge or replace as
and:
soon as possible
Charge or replace at
once
-EN-
( = 50%)
( = 100%)
Version : 2012.1

Publicidad

Tabla de contenido
loading

Tabla de contenido