Helo FONDA STJ Manual Del Usuario página 34

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 63
Product Manual Fonda STJ
Power
Power supply
cable
H07RN –F/
60245 IEC 66
kW
400V 3N~
4,5
5 x 1,5
6,0
5 x 1,5
8,0
5 x 2,5
Table 2 Cable and Fuse
2.11 Electric heating toggle
Electric heating toggle applies to homes with an electric heating system.
Sauna heater has connections (marked N-55) for controlling the electric heating toggle. Connectors
N-55 and the heating elements are simultaneously live (230V). The sauna heater thermostat also
controls the heating toggle. In other words, home heating turns on once the sauna thermostat cuts
power off the sauna heater.
Image 4 Locating the connection box for connection cable in the sauna room
2.12 Location for the connection box
A = Specified minimum safety clearance
1. Recommended location for the connection box
2. Silumin box recommended in this area.
3. This area should be avoided. Always use a silumin box.
In other areas, use a heat-resisting box (T 125 °C) and heat-resisting cables (T 170 °C). The connection box
must be clear of obstacles. When installing the connection box to zones 2 or 3, refer to the instructions and
regulations of the local energy supplier.
Fuse
mm²
A
3 x 10
3 x 10
3 x 16
A
Heater
Power supply
Fuse
cable
H07RN –F/
60245 IEC 66
mm²
A
230V 3~
4 x 2,5
3 x 16
4 x 2,5
3 x 16
4 x 6,0
3 x 25
A
3.
1.
2.
Power supply
Fuse
cable
H07RN –F/
60245 IEC 66
mm²
A
230V 1N~ / 2~
3 x 4,0
1 x 20
3 x 6,0
1 x 35
3 x 6,0
1 x 35
9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

1712-450-1718091712-600-1718091712-800-171809

Tabla de contenido