Heavy arc splatter.
No gas at the end of the torch
Calibration error
Error while downloading
Backup error
Automatic deletion of JOBS.
Push Pull torch detection error
USB key error
File error
Battery
OVERVOLTAGE FAULT
Check the electrical installation
UNDERVOLTAGE FAULT
Check the electrical installation
PHASE FAULT
Check the electrical installation
GENERATOR
Thermal protection
FAN
Fan failure
COOLING UNIT FAILURE
Cooling unit not detected
FAILURE DEBIT
Blocked cooling circuit
WATER LEVEL FAILURE
Check the water level
COLD GROUP
Thermal protection
RISK OF INJURY FROM MOVING COMPONENTS
The reels are equipped with moving components that can catch hands, hair, clothing or tools and cause injuries!
• Do not reach for rotating or moving components or drive parts!
• Make sure that all panels remain closed when in use!
• Do not wear gloves when setting up the wire and changing the wire reel.
WARRANTY
The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).
The warranty does not cover:
• Transit damage.
• Normal wear of parts (eg. : cables, clamps, etc..).
• Damages due to misuse (power supply error, dropping of equipment, disassembling).
• Environment related failures (pollution, rust, dust).
In case of failure, return the unit to your distributor together with:
- The proof of purchase (receipt etc ...)
- A description of the fault reported
54
NEOPULSE 320 C
Arc voltage is too low or too high.
Bad earth clamp connection.
Insufficient gas protection.
Bad gas connection.
An error occurred during the calibration, it is cancel-
led and may be performed again.
The data on the USB stick is incorrect or corrupted.
You have exceeded the maximum number of bac-
kups.
Some of your JOBs has been deleted because they
were incompatible with the new synergies.
-
No JOB is detected on the USB stick
The memory space in the product is full
The"..." file does not correspond to the synergies
downloaded into the product
The battery seems to be worn out
Mains voltage out of tolerance.
Mains voltage out of tolerance.
The installation has a missing or unbalanced phase
- Exceeding the duty cycle.
- Blocked air inlets.
The fan is not running at the right speed.
The cooling unit is not detected.
The debit is below the recommended minimum level
for water cooled torches.
The level is below the minimum
- Exceeding the duty cycle.
- Blocked air inlets.
See welding settings.
Check and put the earth clamp as close as possible to
the welding zone.
Adjust the gas flow.
Check the gas connections
Check that the valve is working properly
Try a new calibration again
Check your data.
You must delete some lines.
The number of backup jobs is limited to 500.
-
Check Push Pull torch connectors
-
Free some space on the USB key.
The file was created with synergies which are not
present on the machine.
Change the battery at the back of the HMI.
Have your electrical installation checked by an autho-
rised person. The voltage between the 3 phases must
be between 340 Veff and 460 Veff.
- Wait for the indicator to turn off before resuming
welding.
- Observe the operating factor and ensure good
ventilation.
- The use of the optional dust filter (ref. 063143)
reduces the duty cycle of the machine.
Please disconnect the machine, check and restart.
Check the connection between the cooling unit and
the appliance.
Check the continuity of the circulation of the
cooling liquid in the torch.
Fill the cooling unit's tank.
- Wait for the indicator to turn off before resuming
welding.
- Dust off the cooling unit by blowing air.