PUMP iNStallatiON
NOticE: Use only PTFE pipe thread sealant tape
for making all threaded connections to the pump
itself. Do not use pipe joint compounds on plastic
pumps: they can react with the plastic in the pump
components. Make sure that all pipe joints in the
suction pipe are air tight as well as water tight. If the
suction pipe can suck air, the pump will not be able to
pull water from the well.
1. Bolt pump to solid, level foundation.
figure 8 – Bolt Pump Down
2. Support all piping connected to the pump.
figure 9 – independently Support all Piping
attached to Pump

Pump/Piping installation

3. Wrap 1-1/2 to two layers of PTFE pipe thread
sealant tape clockwise (as you face end of pipe) on
all male threads being attached to pump.
figure 10 – Use PtfE pipe thread sealant tape on
pipe joints and connections to pump
4. Tighten joints hand tight plus 1-1/2 turns. Do not
overtighten.
532 0405
From
Well
figure 11 – Don't overtighten
NOticE: Install pump as close to well head as
possible. Long piping runs and many fittings create
530 0405
friction and reduce flow.
NOticE: For long horizontal pipe runs, install a
priming tee between check valve and well head as
shown in Figure 6. For driven point installations, install
a check valve as shown in Figure 6. Be sure check
valve flow arrow points toward pump.
Use schedule 80 or iron pipe. See "Well Pipe
Installation" for more information.
5
Use PTFE pipe thread sealant tape or pipe joint
compound approved for use on PVC.
No air leaks In
Suction pipe.
If air flows
water won't
Use PTFE tape.
Don't Hit
Thread Stops
Pump
Body
Hand Tight Plus 1-1/2 Turns With Wrench.
Don't
Overtighten
748 0993