Descargar Imprimir esta página

DeWalt DXCMLA1983054 Manual De Instrucciones página 15

Compresores eléctricos de aire, de una sola etapa y accionamiento por correa

Publicidad

Idiomas disponibles

Idiomas disponibles

Shut-down (Fig. 1)
1. Move Auto/Off switch to the OFF position. NOTE: If finished
using compressor, follow Steps 2 - 6.
2. Pull the regulator knob out and turn counterclockwise until fully
closed. Ensure regulated pressure gauge reads 0 psi. Push
knob in to lock in place.
3. Remove hose and accessory.
WARNING: Risk of unsafe operation. Firmly grasp air hose in hand
when installing or disconnecting to prevent hose whip.
4. Drain the air tank, see Draining Air Tank under Maintenance.
Ensure air tank pressure gauge reads 0 psi.
WARNING: Risk of bursting. Drain air tank daily. Water will
condense in air tank. If not drained, water will corrode and weaken
the air tank causing a risk of air tank rupture.
5. Allow the compressor to cool down.
6. Wipe air compressor clean and store in a safe, non-freezing
area.
MAINTENANCE
Maintenance Chart
Procedure
Check safety valve
Inspect air filter
Drain air tank
15
FIG. 3
OFF
AUTO
OPEN
CLOSE
X
X +
X

Publicidad

loading