Technical Features - Zivan NG3 Manual Del Usuario

Ocultar thumbs Ver también para NG3:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 32

TECHNICAL FEATURES

Ta=25° C unless otherwise specified
Mains side
Description
Supply Voltage
Frequency
Absorbed Maximum Current
Inrush Current
Displacement Factor
Power Factor
Absorbed Minimum Power
Absorbed Maximum Power
Battery side
Description
Output current
Maximum output current
Output current ripple
Absorbed current
Output voltage
Constant output voltage
Thermal compensation of output voltage
Operating range of Temperature Sensor
Output voltage ripple
Maximum power supplied
Output capacity
General
Description
Operating range of temperature
Maximum relative humidity
Switching frequency
Efficiency
Maximum size
Weight
Enclosure class
Protection and Safety
Description
Insulation
Insulation
Insulation
Leakage current
Input fuse
Output fuse
Minimum output voltage of operation (Battery
Detector)
Maximum output voltage
Reverse output polarity
Thermal protection of semiconductors
(Temperature of Thermal Alarm)
Safety Requirements (Rules)
EMC Requirements (Rules)
D01737-08
NG3 Battery Charger
Symbol
Test Condition
Vin
f
Iin
P = P
max
max
-
Vin = 230Veff
P = P
DPF/cosϕ
max
P.F.
P = P
max
Pin
End of charge
min
Pin
P = P
max
max
Symbol
Test Condition
I
I1
Phase 1
-
I = I1
I
Equipment turned off
a
U
U1
Phase 2
dU1/dT
Phase 2
∆T
-
U = U1
P
U = U1, I = I1
max
C
Symbol
Test Condition
∆T
RH
f
c
At each operation condition
η
a×b×c
Without connecting cable
-
Without connecting cable
-
Symbol
Test Condition
-
Mains to Battery side
-
Mains side to Earth
-
Battery side to Earth
I
Supplied equipment
L
F1
Inside the equipment
F2
Inside the equipment
-
Equipment turn on
Um
Phase 3 (IUIa - IUIUo)
-
At the connection to the Battery
-
Ta=55° C
-
EN60335-1, EN60335-2-29
-
EN55014-1, EN61000-3-3
EN55014-2, EN61000-4-2
EN61000-4-4, EN61000-4-5
EN61000-4-6, EN61000-4-11
Value and/or
Range
-
230 ± 10%
-
50 ÷ 60
< 1,35
Value and/or Range
-
See curve
See curve
< 5%
-
See curve
See curve
-5 (programmable)
-
from -20
to +50
< 1%
-
Depend on the model
(>0,2)
Value and/or
Range
-
de -20 a +50
-
-
50 ± 5%
> 85%
430x220x100
-
Value and/or
Range
20/325/32
about 1,2×I1
See curve
Protection provided
by fuse F2
English
Unit
Veff
Hz
22
Aeff
A
-
1
0,68
-
< 5
W
3
kW
Unit
-
A
-
< 0,5
mA
-
V
mV /
(° C·cell)
° C
-
2880
W
mF
Unit
° C
90%
-
kHz
-
mm
5,5
kg
IP20
-
Unit
1250
V
AC
1250
V
AC
1250
V
AC
< 3
mA
A
A
1,5
V/cell
V
-
100
° C
-
-
-
-
17

Publicidad