Care & Cleaning; Periodic Maintenance - Toto EcoPower Manual De Instrucciones

Ocultar thumbs Ver también para EcoPower:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Turn on the water supply at the stop valves and
inspect all the connections for any leaks (see ill. 1).
Place hand under the sensor to activate.
For "C" type controller (ex. TELC105R-C20E): Water will
run for the time period indicated by the model. Water will
not stop when you remove your hand.
For "D" type controller (ex. TELC103R-D20E): Water will
run for the time period indicated by the model, or water
will stop when you remove your hand.
IMPORTANT!
D
o
n
the spout (see ill. 2).
A
v
o
d i
s u
n i
g
a
y n
spout surface.
N
v e
r e
u
e s
p
o
i l
h s
coarse particles, thinners, benzene, acids, alkaline
detergents, or nylon scrub brushes, as they can damage
the surface of the spout.
o T
a s
e f
y l
c
e l
a
n
h t
cloth with diluted dishwashing detergent and dry it with
another soft cloth. If this does not adequately clean the
surface, wipe the area with a neutral detergent and wet cloth.
Check your faucet at least once a month for the following potential problems and to do the
following maintenance procedures:
Check all water connections for signs of leakage.
If the spout is loose, tighten the hexagonal nut underneath the spout for deck-mounted
models.
To tighten the Helix Wall-Mounted Spout:
1. Unscrew the escutcheon, tighten the three screws securing the mounting bracket to the
wall.
2. Reinstall escutcheon.
To tighten the Gooseneck Wall-Mounted Spout
1. Turn off the water supply at the stop valves.
2. Disconnect the spout connecting hose and sensor connector from the controller.
3. Remove the spout from the mounting bracket by removing the set screw on the bottom
of the spout base.
4. Tighten the set screw on the back of the spout, then reinstall the spout on the mounting
bracket.
5. As required, ensure the set screw on the mounting bracket and mounting nuts behind
the sink/wall (refer to "Install the Spout" section) are tight.
INSTALLATION PROCEDURE
Testing After Installation
CARE & CLEANING
Spout and Sensor
o
s t
r c
t a
h c
h t
e
e s
s n
r o
c
e l
a
n
n i
g
m
t a
r e
a i
s l
h t
n i
g
p
o
w
d
e
, r
d
e
e t
g r
e
u s
f r
c a
, e
w
p i
e
t i
s u

PERIODIC MAINTENANCE

Inspect for Leakage
Tighten the Spout
when cleaning
t a
m
y a
c s
a r
c t
h the
e
t n
h t
a
i t
c n
u l
d
s e
n i
g
a
d
a
m
p
e
n
e
d soft
7
ill. 1
CLOSE
OPEN
Check for Leaks
ill. 2
Sensor Area
Outlet

Publicidad

Tabla de contenido
loading

Tabla de contenido