Operating Instructions; Care And Cleaning; Troubleshooting - Toto Air Bath ABA756 Manual Del Propietrario

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

OPERATING INSTRUCTIONS

1) Fill the Bath with Water
Fill the tub to your preference.
NOTE: Be careful not to overfill the bath as the water level will rise when the bather enters the bath.
2) Turn the Air Massage On
Press the ON/OFF button on the keypad to begin the Air Massage.
The intensity level is marked by a small "n" and a number on the display.
NOTE: The massive begins on intensity level 3 ("n-3") or your previous
setting.
3) Change Massage Intensity
Press the +/- button to cycle through the massage intensities. The
Normal mode intensities cycle as follows:
n-3 > 4 > 5 > 4 > 3 > 2 > 1 > 2 > 3
4) Change Massage Modes
Press the Mode button to change between the massage modes. The
modes cycle in the following way:
Normal > Oscillate > Pulse > Normal
NO TE: The controller is designed to shut the blower off after 20 minutes
of continuous running. To restart the blower, press the On/Off button.
Massage Mode 1: Oscillating Massage Mode (OSC):
Oscillating mode gradually cycles through the
intensity settings giving a wave-like, soothing
massage.
Chromotherapy Light (Optional)
To Activate: Press the LED button
• Pressing the LED button again will turn the light off.
Changing the Chromotherapy Mode
• The first press will turn the light on, the second will turn it off, the
third within 2 seconds will start the light in the next mode, etc.
• Chromotherapy modes: Slow Spectrum, Fast Spectrum, Slow
Random Color, Fast Random Color, High Speed Random (color
flashes), Blue-Green Fade, Pure White, Pink, Lavender, Light Blue,
Dark Blue, Light Green, and Dark Green.
MASSAGE MODES
Massage Mode 2: Pulsating Massage Mode (PUL):
Pulsating mode cycles the jets from intensity level
1 to intensity level 5, giving a powerful, penetrating
massage.
4
CARE & CLEANING
Automatic Maintenance Cycle
Drain the tub of water
• Once the sensors no longer detect water, the automatic maintenance timer
begins counting down from 15 minutes. The keypad will alternately display
EJE and the remaining time. The eject cycle begins when the timer counts to
zero.
Air is blown through the jets
• The water removal cycle will run for 2 minutes.
• To manually initiate the Maintenance Cycle, press the ON/Off button for 2
seconds and then release it. The display will flash EJE. 10 seconds later, the
cycle will start.
Failure to follow these care and cleaning instructions will void your warranty.
Wipe the bath using a soft, damp cloth with only a non-abrasive liquid detergent.
• Do not use a dry (powder) cleaner or any cleaner that has abrasives. Do not use a strong acide or a strong alkalai (bleach).
• Using any of the above will cause irreparable damage to the surface and components.
NO TE: Slight scratches can be removed with white automotive polishing paste or extremely fine grain, wet sandpaper (1200-1600 grit).
• Be sure to thoroughly rinse off all cleaners after application.
Clean the Keypad
• Wipe away any dirt on the keypad with a dry cloth. A damp cloth and a small amount of mild detergent can be used on a particularly
dirty keypad.
Bathing Aides
• Bathing products such as sea salts, essential oils, soaps, etc. are suggested for use to enhance the bathing experience. However,
concentrated essential oils should not be applied directly to the skin, tub parts or acrylic. They should be added after the tub is filled.
Be sure to thoroughly rinse the tub after draining.
Cleaning the Optional Pillows
• The pillows (if applicable) should be cleaned at least once a month. Use a mild detergant and damp cloth. A vinyl cleaner can be used
on more stubborn stains. A vinyl rejuvenator liquid can be used to restore the look of the pillows.

TROUBLESHOOTING

Please check the following before calling for service.
PROBLEM
POSSIBLE CAUSE
Completely fails to
A power outage, tripped circuit breaker or tripped
operate
GFCI.
Breaker trips
The breaker amperage is not sufficient or multiple
continuously
electrical devices are connected on one circuit.
The blower is equipped with a thermal shut off
in order to prevent overheating, damage to the
Blower stops after only
blower, or risk of fire. The thermal shut off sensor
a few minutes
may be detecting overheating due to insufficient air
circulation.
Jets do not work at low
Low air volume is moving through the jets. Blower
speed
may be blocked.
Jets do not work at
Air nozzles are clogged or dirty.
high speed
Motor stops after 20
In order to prevent continuous operation, the
minutes
blower automatically shuts off after 20 minutes.
Keypad works, but the
The blower cord may be disconnected or damaged.
blower won't run
Intensity or Modes
The motor or keypad may be damaged.
won't change
Any time the blower is activated or the sensor
EJE appears on the
detects water in the system, the EJE timer will
keypad and cycle starts.
activate.
SOLUTION
Wait until the power is restored. Turn the circuit
breaker back on.
Make sure the bath is the only thing connected to
the breaker circuit and is on a 15 A circuit.
Make sure the blower has sufficient air volume
and is not clogged with debris.
Make sure the blower is clean and has enough air
space to draw from.
Fill the tub with hot water and let it stand for 2
minutes. Turn the jets on and off on the highest
intensity. If this does not fix the problem, contact
your dealer or TOTO for repair.
Restart the blower with the keypad.
Inspect the cord. If it is undamaged, reconnect
it. If damaged, contact your dealer or TOTO for
repair.
Contact your dealer or TOTO for repair.
This is not a malfunction. See page 5 for more
information.
5

Publicidad

Tabla de contenido
loading

Tabla de contenido