Adjustable Stand
Adjust the tool holder angle to suit your work position.
Operation Modes
1. From the main Menu, select the mode to activate the tool depending on the task.
Stand + Autostart ON
Stand + Autostart OFF
Press
Do not
press
Press the start/stop button to
The tool automatically starts
blow hot air.
blowing hot air when lifted
from the stand.
2. The tool stops blowing hot air when returned to the stand.
8
Pedal*
Press
Press the Pedal to blow hot
air and release to stop.
*The P-005 Pedal is not
supplied with this station.
See our website.
Quick Nozzle Changer
Changing nozzles quickly and safely.
1
Turn the tool off
and handle with
care. The heating
element and the
nozzle are still hot.
Compatible Nozzles
The JT-TA works with JT nozzles. Find the model that best suits your soldering needs in www.jbctools.com
Straight
Bent
Flat
Ø mm
Ø mm
A x B mm
In case of a loosely fitting nozzle:
1. Push the nozzle tab inwards with a
screwdriver or flat-nosed pliers.
w w w.jbctools.com
2
Ref.
Shape
Size
JN2020
Straight
Ø 8mm
JN8417
Straight
Ø 10mm
JN2015
Bent
Ø 4mm
JN2012
Bent
Ø 6mm
JN6633
Bent
Ø 8mm
JN7637
Flat
10 x 2mm
JN7638
Flat
20 x 2mm
JN7639
Flat
30 x 2mm
2. Insert the nozzle into the JT-TA Heater again.
9