Victron energy BlueSolar MPPT 150/35 Manual página 4

Ocultar thumbs Ver también para BlueSolar MPPT 150/35:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

1.8 Automatic battery voltage recognition
The MPPT 150/35 will automatically adjust itself to a 12V, 24V or
a 48V system. A computer or a Color Control panel is required to
set the controller to 36V.
1.9 Adaptive three step charging
The BlueSolar MPPT Charge Controller is configured for a three
step charging process: Bulk – Absorption - Float.
1.9.1. Bulk stage
During this stage the controller delivers as much charge current
as possible to rapidly recharge the batteries.
1.9.2. Absorption stage
When the battery voltage reaches the absorption voltage setting,
the controller switches to constant voltage mode.
When only shallow discharges occur the absorption time is kept
short in order to prevent overcharging of the battery. After a deep
discharge the absorption time is automatically increased to make
sure that the battery is completely recharged. Additionally, the
absorption period is also ended when the charge current
decreases to less than 2 A.
1.9.3. Float stage
During this stage, float voltage is applied to the battery to
maintain it in a fully charged state.
1.10 Connectivity
See section 3.8 of this manual.
1.11 Remote on-off
The MPPT 150/35 can be controlled remotely by a VE.Direct non
inverting remote on-off cable (ASS030550300). An input HIGH
(Vi > 8V) will switch the controller on, and an input LOW (V < 2V,
or free floating) will switch the controller off.
Application example: on/off control by a VE.Bus BMS when
charging Li-ion batteries.
2

Publicidad

Tabla de contenido
loading

Tabla de contenido