Safety During Operation - Tecno-gaz Ekstraplus PT001TTM Instrucciones De Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

DOOR OPEN
CYCLE NOT STARTED
SCREEN E106
CYCLE INTERRUPTED
SCREEN E107
8
The cycle can be launched if the door is closed.
The door is locked by the safety device upon the START command and remains blocked until
the cycle is completed.
The door cannot be opened during the cycle.
The cycle is launched from the beginning when START is pressed.
The STOP command interrupts the cycle, resets the functions performed and unlocks the
door.
When there is no disinfectant or oil in the tanks, START is inhibited and this is indicated on
the display. When this signal is given during the cycle, the latter is not interrupted.
When there is no air, START is inhibited and the cycle is interrupted, thereby resetting the
selections.
Safety during the cycle is controlled by software that displays the errors and anomalies during
operation and stores them on the SD card.
OK
MICRO M2 NOT ACTIVE
OK
MICRO M2 NOT ACTIVE

SAFETY DURING OPERATION

CAUSES:
This is displayed when the cycle is launched
with the door open or when the closing device
does not work.
SOLUTIONS:
Press OK to confirm, close the door and restart
the cycle. If the screen with the door closed
means a faulty lock and require a technical
intervention.
CAUSES:
1) If STOP is pressed during operation, the
cycle is interrupted and screen E107
appears.
2) If a fault occurs in the lock during the
cycle, the cycle is interrupted.
SOLUTIONS:
1) Press OK and screen B appears.
2) Request technical support.
ENGLISH
25

Publicidad

Tabla de contenido
loading

Tabla de contenido