PT3A
1.7

Technical Data

Engine
Engine Make
Engine Model
Rated Power
Spark Plug
Electrode Gap
Engine speed
Air Cleaner
Engine Lubrication
Engine Oil Capacity
Fuel
Fuel Tank Capacity
Pump
Weight
*Max. Suction Lift
Max. Total Head
Mechanical Seal Lubrication
Suction / Discharge Dia.
Maximum Solid Size
* Based on pump operating at sea level. Maximum suction lift will be less at higher altitudes.
Sound Measurements
The required sound specifications, per Appendix 1, Paragraph 1.7.4.f of the EC-Machine Regulations, are:
- the sound pressure level at operator's location (L
- the sound power level (L
These sound values were determined according to ISO 3744 for the sound power level (L
the sound pressure level (L
The sound measurements were obtained with the unit operating on pavement at nominal speed.
Hp (kW)
type
in. (mm)
rpm
type
oil grade
oz. (ml)
type
qts. (l)
lbs. (kg)
ft. (m)
ft. (m)
oil grade
oz. (ml)
in. (mm)
in. (mm)
) = 97 dB(A)
WA
) at the operator's location.
pA
Honda
GX 240 K1 QA
8 (6)
(NGK) BPR 6ES
BOSCH WR 7DC
0.028–0.031 (0.7–0.8)
3500 ± 100
Dual element
SAE10W30 - service class SF, SE, SD or SC
37 (1100)
Regular unleaded gasoline
6.4 (6.1 )
164 (74)
*25 (7.5)
95 (29)
SAE 30
Approx. 4 (120)
3 (75)
1.5 (38)
) = 87 dB(A)
pA
OPERATION
) and ISO 6081 for
WA
1A
1A-5