Description
Function
Press the s or t button to
1
select the type of system
you have in your home
2
select whether your
changeover valve is used
in heating or cooling
3
select your heating
system and fan operation
5
select your Stage 1
heating system and
optimize its operation
6
select your Stage 2
heating system and
optimize its operation
8
Emergency Heat Cycle
Rate (heat pumps only)
12
select Manual or Auto
Changeover
13
select Smart Response®
Technology
14
select Fahrenheit or
Celsius temperature
display
Setting
0 Heating & cooling: Gas, oil or electric heating with central
air conditioning.
1 Heat pump: Outside compressor provides both heating and
cooling without backup or auxiliary heat.
2 Heating only: Gas, oil or electric heating without central air
conditioning.
3 Heating only with fan: Gas, oil or electric heating without
central air conditioning. (Use this setting if you could turn the
fan on and off with a fan switch on your old thermostat.)
4 Cool only: Central air conditioning only.
5 Heat pump: Outside compressor provides both heating and
cooling with backup or auxiliary heating.
6 Heat/Cool Multiple Stages: Two heat stages (wires on W
and W2), two cooling stages (wires on Y and Y2).
7 Heat/Cool Multiple Stages: Two heat stages (wires on W
and W2), one cooling stage (wire on Y).
8 Heat/Cool Multiple Stages: One heat stage (wire on W),
two cooling stages (wires on Y and Y2).
0 Cooling changeover valve: Use this setting if you
connected a wire labeled "O" to the O/B W wire terminal.
1 Heating changeover valve: Use this setting if you
connected a wire labeled "B" to the O/B W wire terminal.
0 Gas or oil heat: Use this setting if you have a gas or oil
heating system (system controls fan operation).
1 Electric heat: Use this setting if you have an electric
heating system (thermostat controls fan operation).
5 Gas or oil furnace: Use this setting if you have a standard
gas or oil furnace that is less than 90% efficient.
9 Electric furnace: Use this setting if you have any type of
electric heating system.
3 Heat pump, hot water or high-efficiency furnace: Use
this setting if you have a hot water system or a gas furnace
of greater than 90% efficiency.
1 Gas/oil steam or gravity system: Use this setting if you
have a steam or gravity heat system.
5 Gas or oil furnace: Use this setting if you have a standard
gas or oil furnace that is less than 90% efficient.
9 Electric furnace: Use this setting if you have any type of
electric heating system.
3 Heat pump, hot water or high-efficiency furnace: Use
this setting if you have a hot water system or a gas furnace
of greater than 90% efficiency.
1 Gas/oil steam or gravity system: Use this setting if you
have a steam or gravity heat system.
9 Electric furnace: Electric heating systems.
0 Manual Changeover: (Heat/Off/Cool)
1 Automatic Changeover: (Heat/Off/Cool/Auto) Automatically
turns on heat or cool based on room temperature.
1 Smart Response Technology ON
0 Smart Response Technology OFF
0 Fahrenheit temperature display (°F)
1 Celsius temperature display (°C)