Operation Without Water Feature; Set-Up Fountain/Feature - Oase Filtral UVC 1500 Instrucciones De Uso

Ocultar thumbs Ver también para Filtral UVC 1500:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 41

Operation without water feature

When operating without a water feature, the device can be set up either horizontally or hung up.
(→ Set up the device horizontally)
(→ Hang up the device)
 D, E
Connection to the output of Filtral 1500:
• Use a branch valve in order to connect up the hose for a watercourse/water feature.
• Connection for a Venturi nozzle (optionally available, 70364).
• Do not connect anything to the output.
Connection to the output of Filtral 3000/6000/9000:
• Connecting up the Venturi nozzle provided with scope of delivery (possible with and without a branch valve).
• Hose connection for a watercourse/water feature (possible with and without a branch valve).
• Do not connect anything to the output.
Hand-tighten the bolt connections.
Installation
Set up the device horizontally
Adhere to the following conditions for dry installation:
 F
• Ensure that the connection to the power supply is at least 2 m from the pond.
• Only install the unit below water level.
• Position the device in such a way that the nozzle insert is located above the water level.
• Set up the device horizontally on a firm, mud-free surface.
Hang up the device
Adhere to the following conditions for dry installation:
 G
• Ensure that the connection to the power supply is at least 2 m from the pond.
• Only install the unit below water level.
• Only operate the device without a nozzle pipe and nozzle insert.
• Hang up on the bolts using a cord. Secure the cord on the side of the pond.

Set-up fountain/feature

In order to adapt the water feature, the length and the vertical position of the nozzle pipe need to be altered. The water
flow rate can be regulated using the two flow-rate regulators on the branch valve.
How to proceed:
 H
1. Set the nozzle pipe to the length required.
2. Loosen the union nut, align the nozzle pipe vertically and hand-tighten the union nut once again.
Commissioning/start-up
N O T E
The unit will be destroyed if it is operated with a dimmer. It contains sensitive electrical components.
• Do not connect the unit to a dimmable power supply.
Switching on: Connect the unit to the mains. The unit switches on immediately.
Switching off: Disconnect the unit from the mains.
 I
The viewing window shows that the UVC lamp in the device is working.
- EN -
19

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Filtral uvc 3000Filtral uvc 6000Filtral uvc 9000

Tabla de contenido