Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

11. OPERATION

Always turn your blower on before you begin cooking to establish an air flow in the kitchen. Allow the blower run for a
few minutes to clear the air after you turn off the range.
HC0017
A) Blower OFF Delay touch pad
B) ON/Blower speed control touch pad
C) OFF blower touch pad
A. B
OFF D
LOWER
ELAY TOUCH PAD
When a speed is selected, touch the delay touch pad to activate the delay function. The corresponding speed indicator
LED will start flashing to indicate this function is activated. Touch once for a 5-minute delay, twice for 10-minute delay,
three times for 15-minute delay and four times for a 20-minute delay. The fan will continue to operate for the
programmed minutes and will stop automatically. To cancel the delay function, wait 2 seconds and touch the delay
touch pad once again; the blower will then work in normal mode.
NOTE: The blower speed can be increased - or decreased - during delay mode without starting another delay cycle.
B. ON/B
LOWER SPEED CONTROL TOUCH PAD
Touch this touch pad to turn on the blower at the last selected speed. To change the blower speed, touch the touch
pad again until the desired speed is obtained.
NOTES: 1. Each time you touch on the speed control touch pad, the speed changes by increments of 1 (e.g.: speed
1 to speed 2, to speed 3, and then speed four. From the fourth speed, goes down to speed 1.
2. The last speed used is kept in memory except the fourth, the next time the blower will be turned on, it will
run on speed 3.
HEAT SENTRY
This hood is equipped with a Heat Sentry thermostat. This thermostat is a device that will turn on or speed up the blow-
er if it senses excessive heat above the cooking surface.
1) If blower is OFF - the Heat Sentry turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting – the Heat Sentry turns the blower up to HIGH speed.
When HEAT SENTRY is activated, the first and the last speed blower LEDs are flashing alternately.
When the temperature level drops to normal, the blower will return to its original setting.
The HEAT SENTRY can start the blower even if the hood is turned OFF. In this case, it is impossible to turn
the blower OFF with blower switch. If you must stop the blower, do it from the main electrical panel.
C. OFF
BLOWER TOUCH PAD
Touch this touch pad to turn off the blower. This command also cancels the delay function (if activated).
D. OFF
LIGHTING TOUCH PAD
Touch this touch pad to turn off lighting.
E. H
ALOGEN LIGHT TOUCH PAD
Touch this touch pad to turn on the halogen lamps. The lighting intensity changes by increments of 1 (e.g.: Touch once
for low intensity, once again to get more, up to three times. From the higher intensity, touch once to go back to the lower
intensity.
NOTE:
The last lighting intensity used is kept in memory. The next time the halogen lamps will be turned on, they
will light with the last intensity used.
F. N
/K
IGHTLIGHT
EYBOARD
Touch this touch pad to activate the nightlight. The LED will light to indicate the nightlight is on.
When cleaning the hood, use the keyboard lock. To activate the keyboard lock, touch on this touch pad during 3 seconds;
the LED will flash to indicate the keyboard lock is on. touch on the touch pad and hold for 3 seconds again to stop the
keyboard lock fonction.
NOTES: 1. When cleaning the hood, never spray cleaning agent directly on the controls; spray it on the cleaning
cloth and wipe the control with it. Spraying cleaning agent directly on the control will cause
unexpected keybord activation.
2. When the keyboard lock is on, it stops the HEAT SENTRY.
3. If there is a temporary power failure when the keyboard lock is on, when the power will be restored, the
keyboard lock will still be on.
A
B
D) OFF lighting touch pad
E) Halogen light touch pad
F) Nightlight / keyboard lock touch pad
:
:
WARNING
!
:
:
:
L
:
OCK TOUCH PAD
C
D
- 7 -
E
F

Publicidad