For Your Safety - Saber R50SC0012 Manual De Uso

Ocultar thumbs Ver también para R50SC0012:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

LP Cylinder
The LP cylinder used with your grill must meet the following
requirements:
Use LP cylinders only with these required measurements: 12"
(30.5cm) (diameter) x 18" (45.7cm) (tall) with 20 lb. (9kg) capacity
maximum.
LP cylinders must be constructed and marked in accordance with
specifications for LP cylinders of the U. S. Department of
Transportation (DOT) or for Canada, CAN/CSA-B339, cylinders,
spheres and tubes for transportation of dangerous goods.
Transport Canada (TC). See cylinder collar for marking.
LP cylinder valve must have:
-Type 1 outlet compatible with
regulator or grill.
-Safety relief valve.
-UL listed Overfill Protection
Device (OPD). This OPD safety
feature is identified by a unique triangular hand wheel. Use only
LP cylinders equipped with this type of valve.
LP cylinder must be arranged for vapor withdrawal and include
collar to protect LP cylinder valve. Always keep LP cylinder in
upright position during use, transit or storage.
LP cylinder in upright position for vapor withdrawal
LP (Liquefied Petroleum Gas)
LP gas is nontoxic, odorless and colorless when produced. For
Your Safety, LP gas has been given an odor (similar to rotten
cabbage) so that it can be smelled.
LP gas is highly flammable and may ignite unexpectedly when
mixed with air.
LP Cylinder Filling
Use only licensed and experienced dealers.
LP dealer must purge new cylinder before filling.
Dealer should NEVER fill LP cylinder more than 80% of LP
cylinder volume. Volume of propane in cylinder will vary by
temperature.
A frosty regulator indicates gas overfill. Immediately close LP
cylinder valve and call local LP gas dealer for assistance.
Do not release liquid propane (LP) gas into the atmosphere.
This is a hazardous practice.
To remove gas from LP cylinder, contact an LP dealer or call a
local fire department for assistance. Check the telephone
directory under "Gas Companies" for nearest certified LP
dealers.
4
OPD Hand Wheel
LP Cylinder Exchange
Many retailers that sell grills offer you the option of replacing your
empty LP cylinder through an exchange service. Use only those
reputable exchange companies that inspect, precision fill, test
and certify their cylinders. Exchange your cylinder only for an
OPD safety feature-equipped cylinder as described in the
"LP Cylinder" section of this manual.
Always keep new and exchanged LP cylinders in upright position
during use, transit or storage.
Leak test new and exchanged LP cylinders BEFORE
connecting to grill.
LP Cylinder Leak Test

For your safety

Leak test must be repeated each time LP cylinder is exchanged
or refilled.
Do not smoke during leak test.
Do not use an open flame to check for gas leaks.
Grill must be leak tested outdoors in a well-ventilated area, away
from ignition sources such as gas fired or electrical appliances.
During leak test, keep grill away from open flames or sparks.
Use a clean paintbrush and a 50/50 mild soap and water
solution. Brush soapy solution onto areas indicated by arrows in
figure below.
Do not use household cleaning agents. Damage to gas train
components can result.
WARNING
If "growing" bubbles appear do not use or move the
LP cylinder. Contact an LP gas supplier or your fire
department!

Publicidad

Tabla de contenido
loading

Tabla de contenido