10 Anexo
Register Name
Register Number
Status
1400
PV
1402
Status
1412
SV
1414
Status
1424
TV
1426
Status
1436
QV
1438
Status
2000
PV
2002
SV
2004
TV
2006
QV
2008
Status
2100
PV
2102
SV
2104
TV
2106
QV
2108
Status
2200
PV
2202
SV
2204
TV
2206
QV
2208
Unit Codes for Register 104, 108, 112, 116
Unit Code
32
33
40
41
42
43
44
45
46
76
Type
DWord
DWord
DWord
DWord
DWord
DWord
DWord
DWord
DWord
DWord
DWord
DWord
DWord
DWord
DWord
DWord
DWord
DWord
DWord
Measurement Unit
Degree Celsius
Degree Fahrenheit
US Gallon
Liters
Imperial Gallons
Cubic Meters
Feet
Meters
Barrels
Note
See Register 100
Primary Variable in Byte Order CDAB
See Register 100
Secondary Variable in Byte Order CDAB
See Register 100
Third Variable in Byte Order CDAB
See Register 100
Quarternary Variable in Byte Order CDAB
See Register 100
Primary Variable in Byte Order ABCD (Big Endian)
Secondary Variable in Byte Order ABCD (Big Endian)
Third Variable in Byte Order ABCD (Big Endian)
Quarternary Variable in Byte Order ABCD (Big Endian)
See Register 100
Primary Variable in Byte Order DCBA (Little Endian)
Secondary Variable in Byte Order DCBA (Little Endian)
Third Variable in Byte Order ABCD DCBA (Little Endian)
Quarternary Variable in Byte Order DCBA (Little Endian)
See Register 100
Primary Variable in Byte Order BACD (Middle Endian)
Secondary Variable in Byte Order BACD (Middle Endian)
Third Variable in Byte Order BACD (Middle Endian)
Quarternary Variable in Byte Order BACD (Middle Endian)
VEGAFLEX 86 • Protocolo Modbus y Levelmaster