6.2 - Level two programming (adjustable parameters)
All level 2 functions are set by default as highlighted in grey in Table 5, and may
be modified at any time as explained in Table 6.
The parameters can be set on a scale from 1 to 8. To check the value corre-
Input LED
Parameter
L1
Pause time
L2
Step by step function
L3
Motor speed
L4
Motor discharge after
closing
L5
Motor force
L6
Pedestrian or partial opening
8 – English
sponding to each LED see Table 8. IMPORTANT – In the programming proce-
dure, the maximum time interval that can elapse between activation of one key
and the next is 10 seconds. When this time elapses, the procedure terminates
automatically, memorising the modifications made up until then.o.
TABLE 5 - Second level functions
LED (level)
Value
L1
5 seconds
L2
15 seconds
L3
30 seconds
L4
45 seconds
L5
60 seconds
L6
80 seconds
L7
120 seconds
L8
180 seconds
L1
Open – stop – close – stop
L2
Open – stop – close – open
L3
Open – close – open – close
L4
Apartment block:
• In the opening manoeuvre the "Step by Step" and "Open"
commands have no effect; the "Close" command causes the
movement to be inverted, i.e. the closure of the leaf.
• In the closure manoeuvre the "Step by Step" and "Open"
commands cause the movement to be inverted, i.e. the leaf
to open; the "Close" command has no effect.
L5
Apartment block 2:
• In the opening manoeuvre the "Step by Step" and "Open"
commands have no effect; the "Close" command causes the
movement to be inverted, i.e. the closure of the leaf. If the
transmitted command persists for more than 2 sec-
onds, a "Stop" is performed.
• In the closure manoeuvre the "Step by Step" and "Open"
commands cause the movement to be inverted, i.e. the leaf
to open; the "Close" command has no effect. If the trans-
mitted command persists for more than 2 seconds, a
"Stop" is performed.
L6
Step-by-step 2 (less than 2 sec. generates partial opening).
L7
Hold-to-run: the manoeuvre is performed only if the transmit-
ted command persists; if the command is interrupted the
manoeuvre stops.
L8
Opening in semi-automatic mode, closing in hold-to-run
mode.
L1
Very slow
L2
Slow
L3
Medium
L4
Fast
L5
Very fast
L6
Extremely fast
L7
Fast opening, Slow Closing
L8
Extremely fast Opening, Medium Closing
L1
No discharge
L2
Level 1 - Minimum discharge (about 100 ms)
L3
Level 2 - ...
L4
Level 3 - ...
L5
Level 4 - ...
L6
Level 5 - ...
L7
Level 6 - ...
L8
Level 7 - Maximum discharge (about 800 ms)
L1
Level 1 - Minimum Force
L2
Level 2 - ...
L3
Level 3 - ...
Level 4 - ...
L4
L5
Level 5 - ...
L6
Level 6 - ...
L7
Level 7 - ...
L8
Level 8 - Maximum Force
L1
Pedestrian 1 (opening of leaf M2 to 1/4 of total opening)
L2
Pedestrian 1 (opening of leaf M2 to 1/2 of total opening)
L3
Pedestrian 3 (opening of leaf M2 to 3/4 of total opening)
L4
Pedestrian 4 (Complete opening of leaf 2)
L5
Partial 1 (opening of two leafs to 1/4 of "minimum" opening)
L6
Partial 2 (opening of two leafs to 1/2 of "minimum" opening)
L7
Partial 3 (opening of two leafs to 3/4 of "minimum" opening)
L8
Partial 4 (opening of two leafs to "minimum" opening)
Description
Sets the pause time, namely
the time which lapses before
automatic closure. This will only
take effect if closing is active.
Sets the sequence of com-
mands associated with the
"Step-by-Step", "Open" or
"Close" inputs or the radio con-
trol.
Note – When setting L4, L5,
L7 and L8, the behaviour of
the "Open" and "Close" com-
mands is also modified.
Sets the motor speed during
normal travel.
Sets duration of "short inver-
sion" of both motors after per-
forming a Closing manoeuvre
with the aim of reducing the
final residual thrust, guaran-
teeing adequate closure and
facilitating manual release of the
gearmotor.
Adjusts the force of both mo-
tors
Sets type of opening associa-
ted with "Partial open 1" com-
mand.
In levels L5, L6, L7, L8; "mi-
nimum" opening means the
smaller opening out of M1 and
M2; for example, if M1 opens
to 90° and M2 opens to 110°,
the minimum opening is 90°